Every CVE Search/ Get API key

CVE-2015-1007

A specially crafted configuration file could be used to cause a stack-based buffer overflow...

7.8 High

CVE-2015-1007 is a high vulnerability (CVSS 7.8) in Opto 22 Optodatalink, published March 25, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 2.67%, the 85th percentile. No source names a fixed version.

A specially crafted configuration file could be used to cause a stack-based buffer overflow condition in the OPCTest.exe, which may allow remote code execution on Opto 22 PAC Project Professional versions prior to R9.4008, PAC Project Basic versions prior to R9.4008, PAC Display Basic versions prior to R9.4g, PAC Display Professional versions prior to R9.4g, OptoOPCServer version R9.4c and prior that were installed by PAC Project installer, versions prior to R9.4008, and OptoDataLink version R9.4d and prior that were installed by PAC Project installer, versions prior to R9.4008. Opto 22 suggests upgrading to the new product version as soon as possible.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
Low
Privileges needed
None
User interaction
Required

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

2.67%Up 1.6 points since Feb 4, 2022
90%50%10%1%

What each source reports

NVD Score used 7.8

A specially crafted configuration file could be used to cause a stack-based buffer overflow condition in the OPCTest.exe, which may allow remote code execution on Opto 22 PAC Project Professional versions prior to R9.4008, PAC Project Basic versions prior to R9.4008, PAC Display Basic versions prior to R9.4g, PAC Display Professional versions prior to R9.4g, OptoOPCServer version R9.4c and prior that were installed by PAC Project installer, versions prior to R9.4008, and OptoDataLink version R9.4d and prior that were installed by PAC Project installer, versions prior to R9.4008. Opto 22 suggests upgrading to the new product version as soon as possible.

Record
CVE-2015-1007
CVSS 3.0
7.8 HighCVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS 2.0
9.3 HighAV:N/AC:M/Au:N/C:C/I:C/A:C
Weakness
CWE-121, CWE-119
Updated
2026-11-02
CVE List No score

A specially crafted configuration file could be used to cause a stack-based buffer overflow condition in the OPCTest.exe, which may allow remote code execution on Opto 22 PAC Project Professional versions prior to R9.4008, PAC Project Basic versions prior to R9.4008, PAC Display Basic versions prior to R9.4g, PAC Display Professional versions prior to R9.4g, OptoOPCServer version R9.4c and prior that were installed by PAC Project installer, versions prior to R9.4008, and OptoDataLink version R9.4d and prior that were installed by PAC Project installer, versions prior to R9.4008. Opto 22 suggests upgrading to the new product version as soon as possible.

Record
CVE-2015-1007
Weakness
CWE-121
Updated
2026-11-02
EUVDEUVD-2015-1151 No score

A specially crafted configuration file could be used to cause a stack-based buffer overflow condition in the OPCTest.exe, which may allow remote code execution on Opto 22 PAC Project Professional versions prior to R9.4008, PAC Project Basic versions prior to R9.4008, PAC Display Basic versions prior to R9.4g, PAC Display Professional versions prior to R9.4g, OptoOPCServer version R9.4c and prior that were installed by PAC Project installer, versions prior to R9.4008, and OptoDataLink version R9.4d and prior that were installed by PAC Project installer, versions prior to R9.4008. Opto 22 suggests upgrading to the new product version as soon as possible.

Record
EUVD-2015-1151
Updated
2026-11-03
GitHub AdvisoriesGHSA-qg83-5693-xjqm 7.8

A specially crafted configuration file could be used to cause a stack-based buffer overflow...

A specially crafted configuration file could be used to cause a stack-based buffer overflow condition in the OPCTest.exe, which may allow remote code execution on Opto 22 PAC Project Professional versions prior to R9.4008, PAC Project Basic versions prior to R9.4008, PAC Display Basic versions prior to R9.4g, PAC Display Professional versions prior to R9.4g, OptoOPCServer version R9.4c and prior that were installed by PAC Project installer, versions prior to R9.4008, and OptoDataLink version R9.4d and prior that were installed by PAC Project installer, versions prior to R9.4008. Opto 22 suggests upgrading to the new product version as soon as possible.

Record
GHSA-qg83-5693-xjqm
CVSS 3.0
7.8 HighCVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-119
Updated
2026-11-02

Affected products

History

History
WhenChangedSources
2026-11-03aliasesEUVD
2026-11-02createdCVE List, GitHub Advisories, NVD

References

MoveEnter Open