Every CVE Search/ Get API key

CVE-2016-8352

An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions,...

10.0 Critical

An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEFEC23F3F21 all versions, TCSEFEC23FCF20 all versions, TCSEFEC23FCF21 all versions, and TCSEFEC2CF3F20 all versions. A stack-based buffer overflow can be triggered during the SNMP login authentication process that may allow an attacker to remotely execute code.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

4.16%Up 2.6 points since Feb 4, 2022
90%50%10%1%

What each source reports

NVD Score used 10.0

An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEFEC23F3F21 all versions, TCSEFEC23FCF20 all versions, TCSEFEC23FCF21 all versions, and TCSEFEC2CF3F20 all versions. A stack-based buffer overflow can be triggered during the SNMP login authentication process that may allow an attacker to remotely execute code.

Record
CVE-2016-8352
CVSS 3.0
10.0 CriticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
CVSS 2.0
7.5 HighAV:N/AC:L/Au:N/C:P/I:P/A:P
Weakness
CWE-119
Updated
2026-11-02
CVE List No score

An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEFEC23F3F21 all versions, TCSEFEC23FCF20 all versions, TCSEFEC23FCF21 all versions, and TCSEFEC2CF3F20 all versions. A stack-based buffer overflow can be triggered during the SNMP login authentication process that may allow an attacker to remotely execute code.

Record
CVE-2016-8352
Updated
2026-11-02
EUVDEUVD-2016-9200 No score

An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEFEC23F3F21 all versions, TCSEFEC23FCF20 all versions, TCSEFEC23FCF21 all versions, and TCSEFEC2CF3F20 all versions. A stack-based buffer overflow can be triggered during the SNMP login authentication process that may allow an attacker to remotely execute code.

Record
EUVD-2016-9200
Updated
2026-11-03
GitHub AdvisoriesGHSA-4hw4-vcgq-h32m 10.0

An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions,...

An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEFEC23F3F21 all versions, TCSEFEC23FCF20 all versions, TCSEFEC23FCF21 all versions, and TCSEFEC2CF3F20 all versions. A stack-based buffer overflow can be triggered during the SNMP login authentication process that may allow an attacker to remotely execute code.

Record
GHSA-4hw4-vcgq-h32m
CVSS 3.0
10.0 CriticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Weakness
CWE-119
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2016-8352 is a critical vulnerability (CVSS 10.0) in Schneider-electric Connexium Firmware, published February 13, 2017. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 4.16%, the 90th percentile. No source names a fixed version.

References

MoveEnter Open