Every CVE Search/ Get API key

CVE-2017-12723

A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless...

3.7 Low

A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
High
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
None
Availability
None

Exploit likelihood

0.97%Up 0.4 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 3.7

A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.

Record
CVE-2017-12723
CVSS 3.0
3.7 LowCVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N
CVSS 2.0
4.3 MediumAV:N/AC:M/Au:N/C:P/I:N/A:N
Weakness
CWE-200
Updated
2026-11-02
CVE List No score

A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.

Record
CVE-2017-12723
Updated
2026-11-02
EUVDEUVD-2017-4262 No score

A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.

Record
EUVD-2017-4262
Updated
2026-11-03
GitHub AdvisoriesGHSA-fhwg-33jq-7fjq 3.7

A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless...

A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.

Record
GHSA-fhwg-33jq-7fjq
CVSS 3.0
3.7 LowCVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N
Weakness
CWE-200
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2017-12723 is a low vulnerability (CVSS 3.7) in Smiths-medical Medfusion 4000 Wireless Syringe Infusion Pump, published February 15, 2018. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.97%, the 62nd percentile. No source names a fixed version.

References

MoveEnter Open