CVE-2017-12723
A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless...
A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- High
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- Low
- Integrity
- None
- Availability
- None
Exploit likelihood
What each source reports
NVD Score used
3.7
A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.
- Record
CVE-2017-12723- CVSS 3.0
- 3.7 Low
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N - CVSS 2.0
- 4.3 Medium
AV:N/AC:M/Au:N/C:P/I:N/A:N - Weakness
- CWE-200
- Updated
- 2026-11-02
CVE List No score
A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.
- Record
CVE-2017-12723- Updated
- 2026-11-02
EUVDEUVD-2017-4262 No score
A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.
- Record
EUVD-2017-4262- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-fhwg-33jq-7fjq
3.7
A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless...
A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.
- Record
GHSA-fhwg-33jq-7fjq- CVSS 3.0
- 3.7 Low
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N - Weakness
- CWE-200
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2017-12723 is a low vulnerability (CVSS 3.7) in Smiths-medical Medfusion 4000 Wireless Syringe Infusion Pump, published February 15, 2018. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.97%, the 62nd percentile. No source names a fixed version.