An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants...

6.1 Medium

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
Required

What an attacker can affect

Confidentiality
Low
Integrity
Low
Availability
None

Exploit likelihood

0.87%Up 0.2 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 6.1

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link.

Record
CVE-2017-12738
CVSS 3.0
6.1 MediumCVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
CVSS 2.0
4.3 MediumAV:N/AC:M/Au:N/C:N/I:P/A:N
Weakness
CWE-79
Updated
2026-11-02
CVE List No score

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link.

Record
CVE-2017-12738
Updated
2026-11-02
EUVDEUVD-2017-4277 No score

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link.

Record
EUVD-2017-4277
Updated
2026-11-03
GitHub AdvisoriesGHSA-pqm2-rcwc-h6q3 6.1

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants...

An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link.

Record
GHSA-pqm2-rcwc-h6q3
CVSS 3.0
6.1 MediumCVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Weakness
CWE-79
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2017-12738 is a medium vulnerability (CVSS 6.1) in Siemens Sm-2556 Firmware, published November 15, 2017. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.87%, the 59th percentile. No source names a fixed version.

References

MoveEnter Open