Every CVE Search/ Get API key

CVE-2017-14022

An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and...

7.5 High

An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
None
Integrity
None
Availability
High

Exploit likelihood

4.22%Up 3.6 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 7.5

An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate.

Record
CVE-2017-14022
CVSS 3.0
7.5 HighCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS 2.0
5.0 MediumAV:N/AC:L/Au:N/C:N/I:N/A:P
Weakness
CWE-20
Updated
2026-11-02
CVE List No score

An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate.

Record
CVE-2017-14022
Weakness
CWE-20
Updated
2026-11-02
EUVDEUVD-2017-5537 No score

An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate.

Record
EUVD-2017-5537
Updated
2026-11-03
GitHub AdvisoriesGHSA-64w8-wm29-p94r 7.5

An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and...

An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate.

Record
GHSA-64w8-wm29-p94r
CVSS 3.0
7.5 HighCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness
CWE-20
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2017-14022 is a high vulnerability (CVSS 7.5) in Rockwellautomation Factorytalk Alarms And Events, published December 23, 2017. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 4.22%, the 91st percentile. No source names a fixed version.

References