CVE-2017-17759
Conarc iChannel allows remote attackers to obtain sensitive information, modify the configuration...
Conarc iChannel allows remote attackers to obtain sensitive information, modify the configuration, or cause a denial of service (by deleting the configuration) via a wc.dll?wwMaint~EditConfig request (which reaches an older version of a West Wind Web Connection HTTP service).
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
9.8
Conarc iChannel allows remote attackers to obtain sensitive information, modify the configuration, or cause a denial of service (by deleting the configuration) via a wc.dll?wwMaint~EditConfig request (which reaches an older version of a West Wind Web Connection HTTP service).
- Record
CVE-2017-17759- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 10.0 High
AV:N/AC:L/Au:N/C:C/I:C/A:C - Updated
- 2026-11-02
CVE List No score
Conarc iChannel allows remote attackers to obtain sensitive information, modify the configuration, or cause a denial of service (by deleting the configuration) via a wc.dll?wwMaint~EditConfig request (which reaches an older version of a West Wind Web Connection HTTP service).
- Record
CVE-2017-17759- Updated
- 2026-11-02
EUVDEUVD-2017-8911 No score
Conarc iChannel allows remote attackers to obtain sensitive information, modify the configuration, or cause a denial of service (by deleting the configuration) via a wc.dll?wwMaint~EditConfig request (which reaches an older version of a West Wind Web Connection HTTP service).
- Record
EUVD-2017-8911- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-c5mh-5g96-xq77
9.8
Conarc iChannel allows remote attackers to obtain sensitive information, modify the configuration...
Conarc iChannel allows remote attackers to obtain sensitive information, modify the configuration, or cause a denial of service (by deleting the configuration) via a wc.dll?wwMaint~EditConfig request (which reaches an older version of a West Wind Web Connection HTTP service).
- Record
GHSA-c5mh-5g96-xq77- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Updated
- 2026-11-02
Affected products
Public exploits
Links only. Every CVE stores no exploit code.
| Source | Link | Date |
|---|---|---|
| Exploit-DB | Conarc iChannel - Improper Access Restrictions | 2017-12-20 |
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, Exploit-DB, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2017-17759 is a critical vulnerability (CVSS 9.8) in Conarc Ichannel, published December 19, 2017. Public exploit code exists. EPSS puts the chance of exploitation in the next 30 days at 11.3%, the 96th percentile. No source names a fixed version.