CVE-2017-2300
On Juniper Networks SRX Series Services Gateways chassis clusters running Junos OS 12.1X46 prior...
On Juniper Networks SRX Series Services Gateways chassis clusters running Junos OS 12.1X46 prior to 12.1X46-D65, 12.3X48 prior to 12.3X48-D40, 12.3X48 prior to 12.3X48-D60, flowd daemon on the primary node of an SRX Series chassis cluster may crash and restart when attempting to synchronize a multicast session created via crafted multicast packets.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- None
- Integrity
- None
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
7.5
On Juniper Networks SRX Series Services Gateways chassis clusters running Junos OS 12.1X46 prior to 12.1X46-D65, 12.3X48 prior to 12.3X48-D40, 12.3X48 prior to 12.3X48-D60, flowd daemon on the primary node of an SRX Series chassis cluster may crash and restart when attempting to synchronize a multicast session created via crafted multicast packets.
- Record
CVE-2017-2300- CVSS 3.0
- 7.5 High
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - CVSS 2.0
- 5.0 Medium
AV:N/AC:L/Au:N/C:N/I:N/A:P - Updated
- 2026-11-02
CVE List No score
On Juniper Networks SRX Series Services Gateways chassis clusters running Junos OS 12.1X46 prior to 12.1X46-D65, 12.3X48 prior to 12.3X48-D40, 12.3X48 prior to 12.3X48-D60, flowd daemon on the primary node of an SRX Series chassis cluster may crash and restart when attempting to synchronize a multicast session created via crafted multicast packets.
- Record
CVE-2017-2300- Updated
- 2026-11-02
EUVDEUVD-2017-11483 No score
On Juniper Networks SRX Series Services Gateways chassis clusters running Junos OS 12.1X46 prior to 12.1X46-D65, 12.3X48 prior to 12.3X48-D40, 12.3X48 prior to 12.3X48-D60, flowd daemon on the primary node of an SRX Series chassis cluster may crash and restart when attempting to synchronize a multicast session created via crafted multicast packets.
- Record
EUVD-2017-11483- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-q4mm-jww3-53jr
7.5
On Juniper Networks SRX Series Services Gateways chassis clusters running Junos OS 12.1X46 prior...
On Juniper Networks SRX Series Services Gateways chassis clusters running Junos OS 12.1X46 prior to 12.1X46-D65, 12.3X48 prior to 12.3X48-D40, 12.3X48 prior to 12.3X48-D60, flowd daemon on the primary node of an SRX Series chassis cluster may crash and restart when attempting to synchronize a multicast session created via crafted multicast packets.
- Record
GHSA-q4mm-jww3-53jr- CVSS 3.0
- 7.5 High
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2017-2300 is a high vulnerability (CVSS 7.5) in Juniper Junos, published May 30, 2017. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.84%, the 79th percentile. No source names a fixed version.