CVE-2017-5569
An issue was discovered in eClinicalWorks Patient Portal 7.0 build 13. This is a blind SQL...
An issue was discovered in eClinicalWorks Patient Portal 7.0 build 13. This is a blind SQL injection within the template.jsp, which can be exploited without the need of authentication and via an HTTP POST request, and which can be used to dump database data out to a malicious server, using an out-of-band technique such as select_loadfile().
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
9.8
An issue was discovered in eClinicalWorks Patient Portal 7.0 build 13. This is a blind SQL injection within the template.jsp, which can be exploited without the need of authentication and via an HTTP POST request, and which can be used to dump database data out to a malicious server, using an out-of-band technique such as select_loadfile().
- Record
CVE-2017-5569- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 7.5 High
AV:N/AC:L/Au:N/C:P/I:P/A:P - Weakness
- CWE-89
- Updated
- 2026-11-02
CVE List No score
An issue was discovered in eClinicalWorks Patient Portal 7.0 build 13. This is a blind SQL injection within the template.jsp, which can be exploited without the need of authentication and via an HTTP POST request, and which can be used to dump database data out to a malicious server, using an out-of-band technique such as select_loadfile().
- Record
CVE-2017-5569- Updated
- 2026-11-02
EUVDEUVD-2017-14670 No score
An issue was discovered in eClinicalWorks Patient Portal 7.0 build 13. This is a blind SQL injection within the template.jsp, which can be exploited without the need of authentication and via an HTTP POST request, and which can be used to dump database data out to a malicious server, using an out-of-band technique such as select_loadfile().
- Record
EUVD-2017-14670- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-rp4c-hj8r-248j
9.8
An issue was discovered in eClinicalWorks Patient Portal 7.0 build 13. This is a blind SQL...
An issue was discovered in eClinicalWorks Patient Portal 7.0 build 13. This is a blind SQL injection within the template.jsp, which can be exploited without the need of authentication and via an HTTP POST request, and which can be used to dump database data out to a malicious server, using an out-of-band technique such as select_loadfile().
- Record
GHSA-rp4c-hj8r-248j- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-89
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2017-5569 is a critical vulnerability (CVSS 9.8) in Eclinicalworks Patient Portal, published January 23, 2017. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.98%, the 80th percentile. No source names a fixed version.