An issue was discovered on Vera VeraEdge 1.7.19 and Veralite 1.7.481 devices. The device provides...
An issue was discovered on Vera VeraEdge 1.7.19 and Veralite 1.7.481 devices. The device provides a shell script called connect.sh which is supposed to return a specific cookie for the user when the user is authenticated to https://home.getvera.com. One of the parameters retrieved by this script is "RedirectURL". However, the application lacks strict input validation of this parameter and this allows an attacker to execute the client-side code on this application.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- Required
What an attacker can affect
- Confidentiality
- Low
- Integrity
- Low
- Availability
- None
Exploit likelihood
What each source reports
NVD Score used
6.1
An issue was discovered on Vera VeraEdge 1.7.19 and Veralite 1.7.481 devices. The device provides a shell script called connect.sh which is supposed to return a specific cookie for the user when the user is authenticated to https://home.getvera.com. One of the parameters retrieved by this script is "RedirectURL". However, the application lacks strict input validation of this parameter and this allows an attacker to execute the client-side code on this application.
- Record
CVE-2017-9390- CVSS 3.0
- 6.1 Medium
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N - CVSS 2.0
- 4.3 Medium
AV:N/AC:M/Au:N/C:N/I:P/A:N - Weakness
- CWE-79
- Updated
- 2026-11-02
CVE List No score
An issue was discovered on Vera VeraEdge 1.7.19 and Veralite 1.7.481 devices. The device provides a shell script called connect.sh which is supposed to return a specific cookie for the user when the user is authenticated to https://home.getvera.com. One of the parameters retrieved by this script is "RedirectURL". However, the application lacks strict input validation of this parameter and this allows an attacker to execute the client-side code on this application.
- Record
CVE-2017-9390- Updated
- 2026-11-02
EUVDEUVD-2017-18325 No score
An issue was discovered on Vera VeraEdge 1.7.19 and Veralite 1.7.481 devices. The device provides a shell script called connect.sh which is supposed to return a specific cookie for the user when the user is authenticated to https://home.getvera.com. One of the parameters retrieved by this script is "RedirectURL". However, the application lacks strict input validation of this parameter and this allows an attacker to execute the client-side code on this application.
- Record
EUVD-2017-18325- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-h68v-6hpc-5q95
6.1
An issue was discovered on Vera VeraEdge 1.7.19 and Veralite 1.7.481 devices. The device provides...
An issue was discovered on Vera VeraEdge 1.7.19 and Veralite 1.7.481 devices. The device provides a shell script called connect.sh which is supposed to return a specific cookie for the user when the user is authenticated to https://home.getvera.com. One of the parameters retrieved by this script is "RedirectURL". However, the application lacks strict input validation of this parameter and this allows an attacker to execute the client-side code on this application.
- Record
GHSA-h68v-6hpc-5q95- CVSS 3.0
- 6.1 Medium
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N - Weakness
- CWE-79
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2017-9390 is a medium vulnerability (CVSS 6.1) in Getvera Veraedge Firmware, published June 17, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.53%, the 74th percentile. No source names a fixed version.