Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges....

3.9 Low

Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
High
Privileges needed
High
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
Low
Availability
Low

Exploit likelihood

0.23%Down 0.6 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 3.9

Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.

Record
CVE-2017-9635
CVSS 3.0
3.9 LowCVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L
CVSS 2.0
1.9 LowAV:L/AC:M/Au:N/C:P/I:N/A:N
Weakness
CWE-326
Updated
2026-11-02
CVE List No score

Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.

Record
CVE-2017-9635
Weakness
CWE-326
Updated
2026-11-02
EUVDEUVD-2017-18566 No score

Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.

Record
EUVD-2017-18566
Updated
2026-11-03
GitHub AdvisoriesGHSA-cfpr-7wg7-7x58 3.9

Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges....

Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends that users of Ampla MES versions 6.4 and prior should upgrade to Ampla MES version 6.5 as soon as possible.

Record
GHSA-cfpr-7wg7-7x58
CVSS 3.0
3.9 LowCVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L
Weakness
CWE-326
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2017-9635 is a low vulnerability (CVSS 3.9) in Schneider Electric Se Ampla Mes, published May 18, 2018. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.23%, the 14th percentile. No source names a fixed version.

References

MoveEnter Open