CVE-2017-9852
** DISPUTED ** An Incorrect Password Management issue was discovered in SMA Solar Technology...
An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
9.8
An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
- Record
CVE-2017-9852- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 5.0 Medium
AV:N/AC:L/Au:N/C:P/I:N/A:N - Weakness
- CWE-798
- Updated
- 2026-11-02
CVE List No score
An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
- Record
CVE-2017-9852- Updated
- 2026-11-02
EUVDEUVD-2017-18762 No score
An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
- Record
EUVD-2017-18762- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-2fg4-v4xr-h42m
9.8
** DISPUTED ** An Incorrect Password Management issue was discovered in SMA Solar Technology...
** DISPUTED ** An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected.
- Record
GHSA-2fg4-v4xr-h42m- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-798
- Updated
- 2026-11-02
Affected products
- sma sunny boy 1.5 firmware
- sma sunny boy 2.5 firmware
- sma sunny boy 3.0 firmware
- sma sunny boy 3.6 firmware
- sma sunny boy 3000tl firmware
- sma sunny boy 3600 firmware
- sma sunny boy 3600tl firmware
- sma sunny boy 4.0 firmware
- sma sunny boy 4000tl firmware
- sma sunny boy 5.0 firmware
- sma sunny boy 5000 firmware
- sma sunny boy 5000tl firmware
Show 27 moreShow less
- sma sunny boy storage 2.5 firmware
- sma sunny central 1000cp xt firmware
- sma sunny central 2200 firmware
- sma sunny central 500cp xt firmware
- sma sunny central 630cp xt firmware
- sma sunny central 720cp xt firmware
- sma sunny central 760cp xt firmware
- sma sunny central 800cp xt firmware
- sma sunny central 850cp xt firmware
- sma sunny central 900cp xt firmware
- sma sunny central storage 1000 firmware
- sma sunny central storage 2200 firmware
- sma sunny central storage 2500-ev firmware
- sma sunny central storage 500 firmware
- sma sunny central storage 630 firmware
- sma sunny central storage 720 firmware
- sma sunny central storage 760 firmware
- sma sunny central storage 800 firmware
- sma sunny central storage 850 firmware
- sma sunny central storage 900 firmware
- sma sunny tripower 12000tl firmware
- sma sunny tripower 15000tl firmware
- sma sunny tripower 20000tl firmware
- sma sunny tripower 25000tl firmware
- sma sunny tripower 5000tl firmware
- sma sunny tripower 60 firmware
- sma sunny tripower core1 firmware
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2017-9852 is a critical vulnerability (CVSS 9.8) in Sma Sunny Boy 1.5 Firmware, published August 5, 2017. Its validity is disputed. EPSS puts the chance of exploitation in the next 30 days at 1.72%, the 77th percentile.