CVE-2018-10749
An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long...
An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as a 'commit' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'commit <node_name>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
8.8
An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as a 'commit' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'commit <node_name>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code.
- Record
CVE-2018-10749- CVSS 3.0
- 8.8 High
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 9.0 High
AV:N/AC:L/Au:S/C:C/I:C/A:C - Weakness
- CWE-119
- Updated
- 2026-11-02
CVE List No score
An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as a 'commit' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'commit <node_name>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code.
- Record
CVE-2018-10749- Updated
- 2026-11-02
EUVDEUVD-2018-2819 No score
An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as a 'commit' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'commit <node_name>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code.
- Record
EUVD-2018-2819- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-fr8g-qmx5-jvhc
8.8
An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long...
An issue was discovered on D-Link DSL-3782 EU 1.01 devices. An authenticated user can pass a long buffer as a 'commit' parameter to the '/userfs/bin/tcapi' binary (in the Diagnostics component) using the 'commit <node_name>' function and cause memory corruption. Furthermore, it is possible to redirect the flow of the program and execute arbitrary code.
- Record
GHSA-fr8g-qmx5-jvhc- CVSS 3.0
- 8.8 High
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-119
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2018-10749 is a high vulnerability (CVSS 8.8) in D-link Dsl-3782 Firmware, published May 4, 2018. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 2.56%, the 85th percentile. No source names a fixed version.