CVE-2018-14799
In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018,...
CVE-2018-14799 is a low vulnerability (CVSS 3.7) in Philips Pagewriter Tc10, Tc20, Tc30, Tc50, Tc70 Cardiographs, published August 22, 2018. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.50%, the 42nd percentile. No source names a fixed version.
In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, the PageWriter device does not sanitize data entered by user. This can lead to buffer overflow or format string vulnerabilities.
Attack profile
How easy it is to exploit
- Attack vector
- Physical
- Complexity
- Low
- Privileges needed
- High
- User interaction
- None
What an attacker can affect
- Confidentiality
- Low
- Integrity
- Low
- Availability
- Low
Exploit likelihood
What each source reports
NVD Score used
3.7
In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, the PageWriter device does not sanitize data entered by user. This can lead to buffer overflow or format string vulnerabilities.
- Record
CVE-2018-14799- CVSS 3.0
- 3.7 Low
CVSS:3.0/AV:P/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L - CVSS 2.0
- 4.6 Medium
AV:L/AC:L/Au:N/C:P/I:P/A:P - Weakness
- CWE-20, CWE-119, CWE-134
- Updated
- 2026-11-02
CVE List No score
In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, the PageWriter device does not sanitize data entered by user. This can lead to buffer overflow or format string vulnerabilities.
- Record
CVE-2018-14799- Weakness
- CWE-20
- Updated
- 2026-11-02
EUVDEUVD-2018-6683 No score
In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, the PageWriter device does not sanitize data entered by user. This can lead to buffer overflow or format string vulnerabilities.
- Record
EUVD-2018-6683- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-ccf7-hf4p-q3gc
3.7
In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018,...
In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, the PageWriter device does not sanitize data entered by user. This can lead to buffer overflow or format string vulnerabilities.
- Record
GHSA-ccf7-hf4p-q3gc- CVSS 3.0
- 3.7 Low
CVSS:3.0/AV:P/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L - Weakness
- CWE-119
- Updated
- 2026-11-02
Affected products
History
| When | Changed | Sources |
|---|---|---|
| 2026-11-03 | aliases | EUVD |
| 2026-11-02 | created | CVE List, GitHub Advisories, NVD |