IObit Advanced SystemCare, which includes Monitor_win10_x64.sys or Monitor_win7_x64.sys, 1.2.0.5 ...
IObit Advanced SystemCare, which includes Monitor_win10_x64.sys or Monitor_win7_x64.sys, 1.2.0.5 (and possibly earlier versions) allows a user to send an IOCTL (0x9C402084) with a buffer containing user defined content. The driver's subroutine will execute a rdmsr instruction with the user's buffer for input, and provide output from the instruction.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- None
- Availability
- None
Exploit likelihood
What each source reports
NVD Score used
6.5
IObit Advanced SystemCare, which includes Monitor_win10_x64.sys or Monitor_win7_x64.sys, 1.2.0.5 (and possibly earlier versions) allows a user to send an IOCTL (0x9C402084) with a buffer containing user defined content. The driver's subroutine will execute a rdmsr instruction with the user's buffer for input, and provide output from the instruction.
- Record
CVE-2018-16713- CVSS 3.0
- 6.5 Medium
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N - CVSS 2.0
- 6.8 Medium
AV:N/AC:L/Au:S/C:C/I:N/A:N - Weakness
- CWE-119
- Updated
- 2026-11-02
CVE List No score
IObit Advanced SystemCare, which includes Monitor_win10_x64.sys or Monitor_win7_x64.sys, 1.2.0.5 (and possibly earlier versions) allows a user to send an IOCTL (0x9C402084) with a buffer containing user defined content. The driver's subroutine will execute a rdmsr instruction with the user's buffer for input, and provide output from the instruction.
- Record
CVE-2018-16713- Updated
- 2026-11-02
EUVDEUVD-2018-8514 No score
IObit Advanced SystemCare, which includes Monitor_win10_x64.sys or Monitor_win7_x64.sys, 1.2.0.5 (and possibly earlier versions) allows a user to send an IOCTL (0x9C402084) with a buffer containing user defined content. The driver's subroutine will execute a rdmsr instruction with the user's buffer for input, and provide output from the instruction.
- Record
EUVD-2018-8514- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-jrcf-p229-q8r2
6.5
IObit Advanced SystemCare, which includes Monitor_win10_x64.sys or Monitor_win7_x64.sys, 1.2.0.5 ...
IObit Advanced SystemCare, which includes Monitor_win10_x64.sys or Monitor_win7_x64.sys, 1.2.0.5 (and possibly earlier versions) allows a user to send an IOCTL (0x9C402084) with a buffer containing user defined content. The driver's subroutine will execute a rdmsr instruction with the user's buffer for input, and provide output from the instruction.
- Record
GHSA-jrcf-p229-q8r2- CVSS 3.0
- 6.5 Medium
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N - Weakness
- CWE-119
- Updated
- 2026-11-02
Affected products
Public exploits
Links only. Every CVE stores no exploit code.
| Source | Link | Date |
|---|---|---|
| PoC in GitHub | DownWithUp/CVE-2018-16713 | 2018-09-14 |
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD, PoC in GitHub |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2018-16713 is a medium vulnerability (CVSS 6.5) in Iobit Advanced Systemcare, published September 26, 2018. Public exploit code exists. EPSS puts the chance of exploitation in the next 30 days at 1.86%, the 79th percentile. No source names a fixed version.