An issue was discovered on D-Link DVA-5592 A1_WI_20180823 devices. If the PIN of the page "/ui...
An issue was discovered on D-Link DVA-5592 A1_WI_20180823 devices. If the PIN of the page "/ui/cbpc/login" is the default Parental Control PIN (0000), it is possible to bypass the login form by editing the path of the cookie "sid" generated by the page. The attacker will have access to the router control panel with administrator privileges.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
9.8
An issue was discovered on D-Link DVA-5592 A1_WI_20180823 devices. If the PIN of the page "/ui/cbpc/login" is the default Parental Control PIN (0000), it is possible to bypass the login form by editing the path of the cookie "sid" generated by the page. The attacker will have access to the router control panel with administrator privileges.
- Record
CVE-2018-17777- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 7.5 High
AV:N/AC:L/Au:N/C:P/I:P/A:P - Weakness
- CWE-287
- Updated
- 2026-11-02
CVE List No score
An issue was discovered on D-Link DVA-5592 A1_WI_20180823 devices. If the PIN of the page "/ui/cbpc/login" is the default Parental Control PIN (0000), it is possible to bypass the login form by editing the path of the cookie "sid" generated by the page. The attacker will have access to the router control panel with administrator privileges.
- Record
CVE-2018-17777- Updated
- 2026-11-02
EUVDEUVD-2018-9524 No score
An issue was discovered on D-Link DVA-5592 A1_WI_20180823 devices. If the PIN of the page "/ui/cbpc/login" is the default Parental Control PIN (0000), it is possible to bypass the login form by editing the path of the cookie "sid" generated by the page. The attacker will have access to the router control panel with administrator privileges.
- Record
EUVD-2018-9524- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-r292-8vw9-293g
9.8
An issue was discovered on D-Link DVA-5592 A1_WI_20180823 devices. If the PIN of the page "/ui...
An issue was discovered on D-Link DVA-5592 A1_WI_20180823 devices. If the PIN of the page "/ui/cbpc/login" is the default Parental Control PIN (0000), it is possible to bypass the login form by editing the path of the cookie "sid" generated by the page. The attacker will have access to the router control panel with administrator privileges.
- Record
GHSA-r292-8vw9-293g- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-287
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2018-17777 is a critical vulnerability (CVSS 9.8) in Dlink Dva-5592 Firmware, published December 18, 2018. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.87%, the 79th percentile. No source names a fixed version.