CVE-2018-7297
Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier...
Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to obtain read/write access and execute system commands on the device. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
9.8
Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to obtain read/write access and execute system commands on the device. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.
- Record
CVE-2018-7297- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 10.0 High
AV:N/AC:L/Au:N/C:C/I:C/A:C - Updated
- 2026-11-02
CVE List No score
Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to obtain read/write access and execute system commands on the device. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.
- Record
CVE-2018-7297- Updated
- 2026-11-02
EUVDEUVD-2018-19031 No score
Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to obtain read/write access and execute system commands on the device. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.
- Record
EUVD-2018-19031- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-q64h-3pq3-w59f
9.8
Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier...
Remote Code Execution in the TCL script interpreter in eQ-3 AG Homematic CCU2 2.29.2 and earlier allows remote attackers to obtain read/write access and execute system commands on the device. This vulnerability can be exploited by unauthenticated attackers with access to the web interface.
- Record
GHSA-q64h-3pq3-w59f- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Updated
- 2026-11-02
Affected products
Public exploits
Links only. Every CVE stores no exploit code.
| Source | Link | Date |
|---|---|---|
| Exploit-DB | Homematic CCU2 2.29.23 - Remote Command Execution | 2018-03-30 |
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, Exploit-DB, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2018-7297 is a critical vulnerability (CVSS 9.8) in Eq-3 Homematic Central Control Unit Ccu2 Firmware, published February 22, 2018. Public exploit code exists. EPSS puts the chance of exploitation in the next 30 days at 64.3%, the 99th percentile. No source names a fixed version.