CVE-2018-7675
Potential Information Disclosure in Sentinel
In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After performing some tasks within Sentinel the user does not log out but does go idle for a period of time. This in turn causes the interface to timeout so that it requires the user to re-authenticate. If another user is passing by and decides to login, their credentials are accepted. While The user does not inherit any of the other users privileges, they are able to view the previous screen. In this case it is possible that the user can see another users events or configuration information for whatever view is currently showing.
Attack profile
How easy it is to exploit
- Attack vector
- Local
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- Required
What an attacker can affect
- Confidentiality
- Low
- Integrity
- None
- Availability
- None
Exploit likelihood
What each source reports
CVE List Score used
2.8
Potential Information Disclosure in Sentinel
In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After performing some tasks within Sentinel the user does not log out but does go idle for a period of time. This in turn causes the interface to timeout so that it requires the user to re-authenticate. If another user is passing by and decides to login, their credentials are accepted. While The user does not inherit any of the other users privileges, they are able to view the previous screen. In this case it is possible that the user can see another users events or configuration information for whatever view is currently showing.
- Record
CVE-2018-7675- CVSS 3.0
- 2.8 Low
CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N - Updated
- 2026-11-02
EUVDEUVD-2018-19391
2.8
In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After performing some tasks within Sentinel the user does not log out but does go idle for a period of time. This in turn causes the interface to timeout so that it requires the user to re-authenticate. If another user is passing by and decides to login, their credentials are accepted. While The user does not inherit any of the other users privileges, they are able to view the previous screen. In this case it is possible that the user can see another users events or configuration information for whatever view is currently showing.
- Record
EUVD-2018-19391- CVSS 3.0
- 2.8 Low
CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-m7qw-mwjx-2vpf
5.3
In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After...
In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After performing some tasks within Sentinel the user does not log out but does go idle for a period of time. This in turn causes the interface to timeout so that it requires the user to re-authenticate. If another user is passing by and decides to login, their credentials are accepted. While The user does not inherit any of the other users privileges, they are able to view the previous screen. In this case it is possible that the user can see another users events or configuration information for whatever view is currently showing.
- Record
GHSA-m7qw-mwjx-2vpf- CVSS 3.0
- 5.3 Medium
CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N - Weakness
- CWE-200
- Updated
- 2026-11-02
NVD
2.8
In NetIQ Sentinel before 8.1.x, a Sentinel user is logged into the Sentinel Web Interface. After performing some tasks within Sentinel the user does not log out but does go idle for a period of time. This in turn causes the interface to timeout so that it requires the user to re-authenticate. If another user is passing by and decides to login, their credentials are accepted. While The user does not inherit any of the other users privileges, they are able to view the previous screen. In this case it is possible that the user can see another users events or configuration information for whatever view is currently showing.
- Record
CVE-2018-7675- CVSS 3.0
- 2.8 Low
CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N - CVSS 3.0
- 5.3 Medium
CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N - CVSS 2.0
- 3.5 Low
AV:N/AC:M/Au:S/C:P/I:N/A:N - Weakness
- CWE-200
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2018-7675 is a low vulnerability (CVSS 2.8) in Microfocus Sentinel, published March 7, 2018. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.54%, the 45th percentile. No source names a fixed version.