Every CVE Search/ Get API key

CVE-2018-8857

Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4...

7.8 High

Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) contains fixed credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. An attacker could compromise these credentials and gain access to the system.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.30%Down 0.5 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 7.8

Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) contains fixed credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. An attacker could compromise these credentials and gain access to the system.

Record
CVE-2018-8857
CVSS 3.0
7.8 HighCVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
7.2 HighAV:L/AC:L/Au:N/C:C/I:C/A:C
Weakness
CWE-798
Updated
2026-11-02
CVE List No score

Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) contains fixed credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. An attacker could compromise these credentials and gain access to the system.

Record
CVE-2018-8857
Weakness
CWE-798
Updated
2026-11-02
EUVDEUVD-2018-20465 No score

Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) contains fixed credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. An attacker could compromise these credentials and gain access to the system.

Record
EUVD-2018-20465
Updated
2026-11-03
GitHub AdvisoriesGHSA-qwwm-8j3m-f3mj 7.8

Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4...

Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and Brilliance CT Big Bore 2.3.5 and prior) contains fixed credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. An attacker could compromise these credentials and gain access to the system.

Record
GHSA-qwwm-8j3m-f3mj
CVSS 3.0
7.8 HighCVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-798
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2018-8857 is a high vulnerability (CVSS 7.8) in Philips Brilliance Ct Big Bore Firmware, published May 4, 2018. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.30%, the 23rd percentile. No source names a fixed version.

References

MoveEnter Open