CVE-2019-10332
Jenkins ElectricFlow Plugin missing permission check
A missing permission check in Jenkins ElectricFlow Plugin 1.1.5 and earlier in Configuration#doTestConnection allowed users with Overall/Read access to connect to an attacker-specified URL using attacker-specified credentials.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- Required
What an attacker can affect
- Confidentiality
- None
- Integrity
- Low
- Availability
- None
Exploit likelihood
What each source reports
NVD Score used
4.3
A missing permission check in Jenkins ElectricFlow Plugin 1.1.5 and earlier in Configuration#doTestConnection allowed users with Overall/Read access to connect to an attacker-specified URL using attacker-specified credentials.
- Record
CVE-2019-10332- CVSS 3.1
- 4.3 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N - CVSS 2.0
- 4.3 Medium
AV:N/AC:M/Au:N/C:N/I:P/A:N - Weakness
- CWE-862
- Updated
- 2026-11-02
CVE List No score
A missing permission check in Jenkins ElectricFlow Plugin 1.1.5 and earlier in Configuration#doTestConnection allowed users with Overall/Read access to connect to an attacker-specified URL using attacker-specified credentials.
- Record
CVE-2019-10332- Updated
- 2026-11-02
EUVDEUVD-2022-2729 No score
A missing permission check in Jenkins ElectricFlow Plugin 1.1.5 and earlier in Configuration#doTestConnection allowed users with Overall/Read access to connect to an attacker-specified URL using attacker-specified credentials.
- Record
EUVD-2022-2729- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-66r6-rvv9-9x6m
4.3
Jenkins ElectricFlow Plugin missing permission check
A missing permission check in a form validation method in CloudBees CD Plugin allowed users with Overall/Read permission to initiate a connection test to an attacker-specified server with attacker-specified username and password.
Additionally, the form validation method did not require POST requests, resulting in a CSRF vulnerability.
This form validation method now requires POST requests and Overall/Administer permissions.
- Record
GHSA-66r6-rvv9-9x6m- CVSS 3.0
- 4.3 Medium
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N - Weakness
- CWE-862
- Updated
- 2026-11-02
OSV
4.3
A missing permission check in Jenkins ElectricFlow Plugin 1.1.5 and earlier in Configuration#doTestConnection allowed users with Overall/Read access to connect to an attacker-specified URL using attacker-specified credentials.
- Record
CVE-2019-10332- CVSS 3.1
- 4.3 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N - Updated
- 2026-11-02
OSVGHSA-66r6-rvv9-9x6m
4.3
Jenkins ElectricFlow Plugin missing permission check
A missing permission check in a form validation method in CloudBees CD Plugin allowed users with Overall/Read permission to initiate a connection test to an attacker-specified server with attacker-specified username and password.
Additionally, the form validation method did not require POST requests, resulting in a CSRF vulnerability.
This form validation method now requires POST requests and Overall/Administer permissions.
- Record
GHSA-66r6-rvv9-9x6m- CVSS 3.0
- 4.3 Medium
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N - Weakness
- CWE-862
- Updated
- 2026-11-02
Affected products
Affected packages
| Package | Affected | Fixed |
|---|---|---|
org.jenkins-ci.plugins:electricflowMaven |
through 1.1.6 | 1.1.7 |
org.jenkins-ci.plugins:electricflowMaven |
before 1.1.7, plus listed versions 1.01.1.11.1.21.1.31.1.41.1.51.1.6 |
1.1.7 |
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD, OSV |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2019-10332 is a medium vulnerability (CVSS 4.3) in Jenkins Electricflow, published June 11, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.83%, the 78th percentile. Fixed in org.jenkins-ci.plugins:electricflow 1.1.7.