CVE-2019-10928
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with...
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.
Attack profile
How easy it is to exploit
- Attack vector
- Physical
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
6.6
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.
- Record
CVE-2019-10928- CVSS 3.1
- 6.6 Medium
CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 4.6 Medium
AV:L/AC:L/Au:N/C:P/I:P/A:P - Weakness
- CWE-703
- Updated
- 2026-11-02
CVE List No score
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.
- Record
CVE-2019-10928- Weakness
- CWE-703
- Updated
- 2026-11-02
EUVDEUVD-2019-2642 No score
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.
- Record
EUVD-2019-2642- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-m34p-92f7-v94j No score
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with...
A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.
- Record
GHSA-m34p-92f7-v94j- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases, products | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2019-10928 is a medium vulnerability (CVSS 6.6) in Siemens Scalance Sc-600, published August 13, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.41%, the 35th percentile. No source names a fixed version.