Every CVE Search/ Get API key

CVE-2019-11891

Incorrect privilege assignment in the app pairing mechanism of the Bosch Smart Home Controller (SHC)

8.0 High

A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.

Attack profile

How easy it is to exploit

Attack vector
Adjacent network
Complexity
Low
Privileges needed
None
User interaction
Required

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.54%Up 0.1 points since Apr 14, 2021
90%50%10%1%

What each source reports

CVE List Score used 8.0

Incorrect privilege assignment in the app pairing mechanism of the Bosch Smart Home Controller (SHC)

A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.

Record
CVE-2019-11891
CVSS 3.0
8.0 HighCVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-266
Updated
2026-11-02
EUVDEUVD-2019-3549 8.0

A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.

Record
EUVD-2019-3549
CVSS 3.0
8.0 HighCVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Updated
2026-11-03
GitHub AdvisoriesGHSA-ghfv-mcwg-v5xw 8.0

A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of...

A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.

Record
GHSA-ghfv-mcwg-v5xw
CVSS 3.1
8.0 HighCVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-266, CWE-269
Updated
2026-11-02
NVD 8.0

A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.

Record
CVE-2019-11891
CVSS 3.1
8.0 HighCVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS 3.0
8.0 HighCVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS 2.0
5.4 MediumAV:A/AC:M/Au:N/C:P/I:P/A:P
Weakness
CWE-266, CWE-269
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2019-11891 is a high vulnerability (CVSS 8.0) in Bosch Smart Home Controller, published May 29, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.54%, the 45th percentile. No source names a fixed version.

References

MoveEnter Open