CVE-2019-11891
Incorrect privilege assignment in the app pairing mechanism of the Bosch Smart Home Controller (SHC)
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.
Attack profile
How easy it is to exploit
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- Required
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
8.0
Incorrect privilege assignment in the app pairing mechanism of the Bosch Smart Home Controller (SHC)
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.
- Record
CVE-2019-11891- CVSS 3.0
- 8.0 High
CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H - Weakness
- CWE-266
- Updated
- 2026-11-02
EUVDEUVD-2019-3549
8.0
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.
- Record
EUVD-2019-3549- CVSS 3.0
- 8.0 High
CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-ghfv-mcwg-v5xw
8.0
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of...
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.
- Record
GHSA-ghfv-mcwg-v5xw- CVSS 3.1
- 8.0 High
CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H - Weakness
- CWE-266, CWE-269
- Updated
- 2026-11-02
NVD
8.0
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.
- Record
CVE-2019-11891- CVSS 3.1
- 8.0 High
CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H - CVSS 3.0
- 8.0 High
CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H - CVSS 2.0
- 5.4 Medium
AV:A/AC:M/Au:N/C:P/I:P/A:P - Weakness
- CWE-266, CWE-269
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases, published | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short