Every CVE Search/ Get API key

CVE-2019-11896

Incorrect pviilege assignment in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC)

5.5 Medium

A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app, which requires user interaction.

Attack profile

How easy it is to exploit

Attack vector
Adjacent network
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
Low
Availability
Low

Exploit likelihood

0.67%Up 0.3 points since Apr 14, 2021
90%50%10%1%

What each source reports

CVE List Score used 5.5

Incorrect pviilege assignment in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC)

A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app, which requires user interaction.

Record
CVE-2019-11896
CVSS 3.0
5.5 MediumCVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Weakness
CWE-284
Updated
2026-11-02
EUVDEUVD-2019-3554 5.5

A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app, which requires user interaction.

Record
EUVD-2019-3554
CVSS 3.0
5.5 MediumCVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Updated
2026-11-03
GitHub AdvisoriesGHSA-qfhr-mxhr-cf29 7.1

A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing...

A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app, which requires user interaction.

Record
GHSA-qfhr-mxhr-cf29
CVSS 3.1
7.1 HighCVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-269, CWE-284
Updated
2026-11-02
NVD 7.1

A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app, which requires user interaction.

Record
CVE-2019-11896
CVSS 3.1
7.1 HighCVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS 3.0
5.5 MediumCVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CVSS 2.0
6.8 MediumAV:N/AC:M/Au:N/C:P/I:P/A:P
Weakness
CWE-284, CWE-269
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2019-11896 is a medium vulnerability (CVSS 5.5) in Bosch Smart Home Controller, published May 29, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.67%, the 52nd percentile. No source names a fixed version.

References

MoveEnter Open