CVE-2019-14451
RepetierServer.exe in Repetier-Server 0.8 through 0.91 does not properly validate the XML data...
RepetierServer.exe in Repetier-Server 0.8 through 0.91 does not properly validate the XML data structure provided when uploading a new printer configuration. When this is combined with CVE-2019-14450, an attacker can upload an "external command" configuration as a printer configuration, and achieve remote code execution. After exploitation, loading of the external command configuration is dependent on a system reboot or service restart.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
9.8
RepetierServer.exe in Repetier-Server 0.8 through 0.91 does not properly validate the XML data structure provided when uploading a new printer configuration. When this is combined with CVE-2019-14450, an attacker can upload an "external command" configuration as a printer configuration, and achieve remote code execution. After exploitation, loading of the external command configuration is dependent on a system reboot or service restart.
- Record
CVE-2019-14451- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 10.0 High
AV:N/AC:L/Au:N/C:C/I:C/A:C - Weakness
- CWE-434
- Updated
- 2026-11-02
CVE List No score
RepetierServer.exe in Repetier-Server 0.8 through 0.91 does not properly validate the XML data structure provided when uploading a new printer configuration. When this is combined with CVE-2019-14450, an attacker can upload an "external command" configuration as a printer configuration, and achieve remote code execution. After exploitation, loading of the external command configuration is dependent on a system reboot or service restart.
- Record
CVE-2019-14451- Updated
- 2026-11-02
EUVDEUVD-2019-5640 No score
RepetierServer.exe in Repetier-Server 0.8 through 0.91 does not properly validate the XML data structure provided when uploading a new printer configuration. When this is combined with CVE-2019-14450, an attacker can upload an "external command" configuration as a printer configuration, and achieve remote code execution. After exploitation, loading of the external command configuration is dependent on a system reboot or service restart.
- Record
EUVD-2019-5640- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-rhq4-59ww-jw9j
9.8
RepetierServer.exe in Repetier-Server 0.8 through 0.91 does not properly validate the XML data...
RepetierServer.exe in Repetier-Server 0.8 through 0.91 does not properly validate the XML data structure provided when uploading a new printer configuration. When this is combined with CVE-2019-14450, an attacker can upload an "external command" configuration as a printer configuration, and achieve remote code execution. After exploitation, loading of the external command configuration is dependent on a system reboot or service restart.
- Record
GHSA-rhq4-59ww-jw9j- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-434
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2019-14451 is a critical vulnerability (CVSS 9.8) in Repetier-server, published October 25, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 4.45%, the 91st percentile. No source names a fixed version.