CVE-2019-15654
Comba AP2600-I devices through A02,0202N00PD2 are prone to password disclosure via a simple...
Comba AC2400 devices are prone to password disclosure via a simple crafted /09/business/upgrade/upcfgAction.php?download=true request to the web management server. The request doesn't require any authentication and will lead to saving the DBconfig.cfg file. At the end of the file, the login information is stored in cleartext.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- None
- Availability
- None
Exploit likelihood
What each source reports
NVD Score used
7.5
Comba AC2400 devices are prone to password disclosure via a simple crafted /09/business/upgrade/upcfgAction.php?download=true request to the web management server. The request doesn't require any authentication and will lead to saving the DBconfig.cfg file. At the end of the file, the login information is stored in cleartext.
- Record
CVE-2019-15654- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - CVSS 2.0
- 5.0 Medium
AV:N/AC:L/Au:N/C:P/I:N/A:N - Weakness
- CWE-306
- Updated
- 2026-11-02
CVE List No score
Comba AC2400 devices are prone to password disclosure via a simple crafted /09/business/upgrade/upcfgAction.php?download=true request to the web management server. The request doesn't require any authentication and will lead to saving the DBconfig.cfg file. At the end of the file, the login information is stored in cleartext.
- Record
CVE-2019-15654- Updated
- 2026-11-02
EUVDEUVD-2019-6606 No score
Comba AC2400 devices are prone to password disclosure via a simple crafted /09/business/upgrade/upcfgAction.php?download=true request to the web management server. The request doesn't require any authentication and will lead to saving the DBconfig.cfg file. At the end of the file, the login information is stored in cleartext.
- Record
EUVD-2019-6606- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-7xq3-42gv-rc2r
7.5
Comba AP2600-I devices through A02,0202N00PD2 are prone to password disclosure via a simple...
Comba AP2600-I devices through A02,0202N00PD2 are prone to password disclosure via a simple crafted /09/business/upgrade/upcfgAction.php?download=true request to the web management server. The request doesn't require any authentication and will lead to saving the DBconfig.cfg file. At the end of the file, the login information is stored in cleartext.
- Record
GHSA-7xq3-42gv-rc2r- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - Weakness
- CWE-306, CWE-522
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2019-15654 is a high vulnerability (CVSS 7.5) in Comba Ac2400 Firmware, published March 19, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.59%, the 75th percentile. No source names a fixed version.