Every CVE Search/ Get API key

CVE-2019-15654

Comba AP2600-I devices through A02,0202N00PD2 are prone to password disclosure via a simple...

7.5 High

Comba AC2400 devices are prone to password disclosure via a simple crafted /09/business/upgrade/upcfgAction.php?download=true request to the web management server. The request doesn't require any authentication and will lead to saving the DBconfig.cfg file. At the end of the file, the login information is stored in cleartext.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
None
Availability
None

Exploit likelihood

1.59%Up 0.9 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 7.5

Comba AC2400 devices are prone to password disclosure via a simple crafted /09/business/upgrade/upcfgAction.php?download=true request to the web management server. The request doesn't require any authentication and will lead to saving the DBconfig.cfg file. At the end of the file, the login information is stored in cleartext.

Record
CVE-2019-15654
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CVSS 2.0
5.0 MediumAV:N/AC:L/Au:N/C:P/I:N/A:N
Weakness
CWE-306
Updated
2026-11-02
CVE List No score

Comba AC2400 devices are prone to password disclosure via a simple crafted /09/business/upgrade/upcfgAction.php?download=true request to the web management server. The request doesn't require any authentication and will lead to saving the DBconfig.cfg file. At the end of the file, the login information is stored in cleartext.

Record
CVE-2019-15654
Updated
2026-11-02
EUVDEUVD-2019-6606 No score

Comba AC2400 devices are prone to password disclosure via a simple crafted /09/business/upgrade/upcfgAction.php?download=true request to the web management server. The request doesn't require any authentication and will lead to saving the DBconfig.cfg file. At the end of the file, the login information is stored in cleartext.

Record
EUVD-2019-6606
Updated
2026-11-03
GitHub AdvisoriesGHSA-7xq3-42gv-rc2r 7.5

Comba AP2600-I devices through A02,0202N00PD2 are prone to password disclosure via a simple...

Comba AP2600-I devices through A02,0202N00PD2 are prone to password disclosure via a simple crafted /09/business/upgrade/upcfgAction.php?download=true request to the web management server. The request doesn't require any authentication and will lead to saving the DBconfig.cfg file. At the end of the file, the login information is stored in cleartext.

Record
GHSA-7xq3-42gv-rc2r
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Weakness
CWE-306, CWE-522
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2019-15654 is a high vulnerability (CVSS 7.5) in Comba Ac2400 Firmware, published March 19, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.59%, the 75th percentile. No source names a fixed version.

References

MoveEnter Open