Every CVE Search/ Get API key

CVE-2019-16672

An issue was discovered on Weidmueller IE-SW-VL05M 3.6.6 Build 16102415, IE-SW-VL08MT 3.5.2 Build...

9.8 Critical

An issue was discovered on Weidmueller IE-SW-VL05M 3.6.6 Build 16102415, IE-SW-VL08MT 3.5.2 Build 16102415, and IE-SW-PL10M 3.3.16 Build 16102416 devices. Sensitive Credentials data is transmitted in cleartext.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

1.28%Up 0.2 points since Apr 14, 2021
90%50%10%1%

What each source reports

CVE List Score used 9.8

An issue was discovered on Weidmueller IE-SW-VL05M 3.6.6 Build 16102415, IE-SW-VL08MT 3.5.2 Build 16102415, and IE-SW-PL10M 3.3.16 Build 16102416 devices. Sensitive Credentials data is transmitted in cleartext.

Record
CVE-2019-16672
CVSS 3.0
9.8 CriticalCVSS:3.0/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:N
Updated
2026-11-02
EUVDEUVD-2019-7234 9.8

An issue was discovered on Weidmueller IE-SW-VL05M 3.6.6 Build 16102415, IE-SW-VL08MT 3.5.2 Build 16102415, and IE-SW-PL10M 3.3.16 Build 16102416 devices. Sensitive Credentials data is transmitted in cleartext.

Record
EUVD-2019-7234
CVSS 3.0
9.8 CriticalCVSS:3.0/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:N
Updated
2026-11-03
GitHub AdvisoriesGHSA-mm5m-g4fx-pch2 9.8

An issue was discovered on Weidmueller IE-SW-VL05M 3.6.6 Build 16102415, IE-SW-VL08MT 3.5.2 Build...

An issue was discovered on Weidmueller IE-SW-VL05M 3.6.6 Build 16102415, IE-SW-VL08MT 3.5.2 Build 16102415, and IE-SW-PL10M 3.3.16 Build 16102416 devices. Sensitive Credentials data is transmitted in cleartext.

Record
GHSA-mm5m-g4fx-pch2
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-311, CWE-319
Updated
2026-11-02
NVD 9.8

An issue was discovered on Weidmueller IE-SW-VL05M 3.6.6 Build 16102415, IE-SW-VL08MT 3.5.2 Build 16102415, and IE-SW-PL10M 3.3.16 Build 16102416 devices. Sensitive Credentials data is transmitted in cleartext.

Record
CVE-2019-16672
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 3.0
9.8 CriticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
5.0 MediumAV:N/AC:L/Au:N/C:P/I:N/A:N
Weakness
CWE-319, CWE-522
Updated
2026-11-02

Affected products

Show 28 moreShow less

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2019-16672 is a critical vulnerability (CVSS 9.8) in Weidmueller Ie-sw-pl08m-6tx-2sc Firmware, published December 6, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.28%, the 70th percentile. No source names a fixed version.

References

MoveEnter Open