CVE-2019-17215
An issue was discovered on V-Zug Combi-Steam MSLQ devices before Ethernet R07 and before WLAN R05...
An issue was discovered on V-Zug Combi-Steam MSLQ devices before Ethernet R07 and before WLAN R05. There is no bruteforce protection (e.g., lockout) established. An attacker might be able to bruteforce the password to authenticate on the device.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
9.8
An issue was discovered on V-Zug Combi-Steam MSLQ devices before Ethernet R07 and before WLAN R05. There is no bruteforce protection (e.g., lockout) established. An attacker might be able to bruteforce the password to authenticate on the device.
- Record
CVE-2019-17215- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 5.0 Medium
AV:N/AC:L/Au:N/C:N/I:P/A:N - Weakness
- CWE-307
- Updated
- 2026-11-02
CVE List No score
An issue was discovered on V-Zug Combi-Steam MSLQ devices before Ethernet R07 and before WLAN R05. There is no bruteforce protection (e.g., lockout) established. An attacker might be able to bruteforce the password to authenticate on the device.
- Record
CVE-2019-17215- Updated
- 2026-11-02
EUVDEUVD-2019-7635 No score
An issue was discovered on V-Zug Combi-Steam MSLQ devices before Ethernet R07 and before WLAN R05. There is no bruteforce protection (e.g., lockout) established. An attacker might be able to bruteforce the password to authenticate on the device.
- Record
EUVD-2019-7635- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-vxgh-rfhr-mp4q
9.8
An issue was discovered on V-Zug Combi-Steam MSLQ devices before Ethernet R07 and before WLAN R05...
An issue was discovered on V-Zug Combi-Steam MSLQ devices before Ethernet R07 and before WLAN R05. There is no bruteforce protection (e.g., lockout) established. An attacker might be able to bruteforce the password to authenticate on the device.
- Record
GHSA-vxgh-rfhr-mp4q- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-307
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2019-17215 is a critical vulnerability (CVSS 9.8) in Vzug Combi-stream Mslq Firmware, published October 6, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.18%, the 67th percentile. No source names a fixed version.