Cisco FXOS and NX-OS Software Sensitive File Read Information Disclosure Vulnerability

5.5 Medium

A vulnerability in the implementation of a CLI diagnostic command in Cisco FXOS Software and Cisco NX-OS Software could allow an authenticated, local attacker to view sensitive system files that should be restricted. The attacker could use this information to conduct additional reconnaissance attacks. The vulnerability is due to incomplete role-based access control (RBAC) verification. An attacker could exploit this vulnerability by authenticating to the device and issuing a specific CLI diagnostic command with crafted user-input parameters. An exploit could allow the attacker to perform an arbitrary read of a file on the device, and the file may contain sensitive information. The attacker needs valid device credentials to exploit this vulnerability.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
None
Availability
None

Exploit likelihood

0.33%Up 0.1 points since Apr 14, 2021
90%50%10%1%

What each source reports

CVE List Score used 5.5

Cisco FXOS and NX-OS Software Sensitive File Read Information Disclosure Vulnerability

A vulnerability in the implementation of a CLI diagnostic command in Cisco FXOS Software and Cisco NX-OS Software could allow an authenticated, local attacker to view sensitive system files that should be restricted. The attacker could use this information to conduct additional reconnaissance attacks. The vulnerability is due to incomplete role-based access control (RBAC) verification. An attacker could exploit this vulnerability by authenticating to the device and issuing a specific CLI diagnostic command with crafted user-input parameters. An exploit could allow the attacker to perform an arbitrary read of a file on the device, and the file may contain sensitive information. The attacker needs valid device credentials to exploit this vulnerability.

Record
CVE-2019-1734
CVSS 3.0
5.5 MediumCVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Weakness
CWE-200
Updated
2026-11-02
EUVDEUVD-2019-10291 5.5

A vulnerability in the implementation of a CLI diagnostic command in Cisco FXOS Software and Cisco NX-OS Software could allow an authenticated, local attacker to view sensitive system files that should be restricted. The attacker could use this information to conduct additional reconnaissance attacks. The vulnerability is due to incomplete role-based access control (RBAC) verification. An attacker could exploit this vulnerability by authenticating to the device and issuing a specific CLI diagnostic command with crafted user-input parameters. An exploit could allow the attacker to perform an arbitrary read of a file on the device, and the file may contain sensitive information. The attacker needs valid device credentials to exploit this vulnerability.

Record
EUVD-2019-10291
CVSS 3.0
5.5 MediumCVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Updated
2026-11-03
GitHub AdvisoriesGHSA-ccrq-mrj7-rq78 5.5

A vulnerability in the implementation of a CLI diagnostic command in Cisco FXOS Software and...

A vulnerability in the implementation of a CLI diagnostic command in Cisco FXOS Software and Cisco NX-OS Software could allow an authenticated, local attacker to view sensitive system files that should be restricted. The attacker could use this information to conduct additional reconnaissance attacks. The vulnerability is due to incomplete role-based access control (RBAC) verification. An attacker could exploit this vulnerability by authenticating to the device and issuing a specific CLI diagnostic command with crafted user-input parameters. An exploit could allow the attacker to perform an arbitrary read of a file on the device, and the file may contain sensitive information. The attacker needs valid device credentials to exploit this vulnerability.

Record
GHSA-ccrq-mrj7-rq78
CVSS 3.1
5.5 MediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Weakness
CWE-200
Updated
2026-11-02
NVD 5.5

A vulnerability in the implementation of a CLI diagnostic command in Cisco FXOS Software and Cisco NX-OS Software could allow an authenticated, local attacker to view sensitive system files that should be restricted. The attacker could use this information to conduct additional reconnaissance attacks. The vulnerability is due to incomplete role-based access control (RBAC) verification. An attacker could exploit this vulnerability by authenticating to the device and issuing a specific CLI diagnostic command with crafted user-input parameters. An exploit could allow the attacker to perform an arbitrary read of a file on the device, and the file may contain sensitive information. The attacker needs valid device credentials to exploit this vulnerability.

Record
CVE-2019-1734
CVSS 3.1
5.5 MediumCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
CVSS 3.0
5.5 MediumCVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
CVSS 2.0
2.1 LowAV:L/AC:L/Au:N/C:P/I:N/A:N
Weakness
CWE-200
Updated
2026-11-02

Affected products