CVE-2019-18252

BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple...

4.3 Medium

BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple authentication purposes. An attacker with adjacent access to the CardioMessenger can disclose its credentials used for connecting to the BIOTRONIK Remote Communication infrastructure.

Attack profile

How easy it is to exploit

Attack vector
Adjacent network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
None
Availability
None

Exploit likelihood

0.48%Up 0.1 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 4.3

BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple authentication purposes. An attacker with adjacent access to the CardioMessenger can disclose its credentials used for connecting to the BIOTRONIK Remote Communication infrastructure.

Record
CVE-2019-18252
CVSS 3.1
4.3 MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
CVSS 2.0
3.3 LowAV:A/AC:L/Au:N/C:P/I:N/A:N
Weakness
CWE-287
Updated
2026-11-02
CVE List No score

BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple authentication purposes. An attacker with adjacent access to the CardioMessenger can disclose its credentials used for connecting to the BIOTRONIK Remote Communication infrastructure.

Record
CVE-2019-18252
Weakness
CWE-287
Updated
2026-11-02
EUVDEUVD-2019-8050 No score

BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple authentication purposes. An attacker with adjacent access to the CardioMessenger can disclose its credentials used for connecting to the BIOTRONIK Remote Communication infrastructure.

Record
EUVD-2019-8050
Updated
2026-11-03
GitHub AdvisoriesGHSA-2f8f-gw52-m98c No score

BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple...

BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple authentication purposes. An attacker with adjacent access to the CardioMessenger can disclose its credentials used for connecting to the BIOTRONIK Remote Communication infrastructure.

Record
GHSA-2f8f-gw52-m98c
Weakness
CWE-287
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2019-18252 is a medium vulnerability (CVSS 4.3) in Biotronik Cardiomessenger Ii-s Gsm Firmware, published June 29, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.48%, the 41st percentile. No source names a fixed version.