CVE-2019-18336
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and...
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- None
- Integrity
- None
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
7.5
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
- Record
CVE-2019-18336- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - CVSS 2.0
- 7.8 High
AV:N/AC:L/Au:N/C:N/I:N/A:C - Weakness
- CWE-400
- Updated
- 2026-11-02
CVE List
7.5
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
- Record
CVE-2019-18336- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - Weakness
- CWE-400
- Updated
- 2026-11-02
EUVDEUVD-2019-8125
7.5
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
- Record
EUVD-2019-8125- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-q53p-vg4g-3rxp
7.5
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and...
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SINUMERIK 840D sl (All versions). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
- Record
GHSA-q53p-vg4g-3rxp- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - Weakness
- CWE-400
- Updated
- 2026-11-02
Affected products
- siemens simatic s7-300 cpu family (incl. related et200 cpus and siplus variants)
- siemens simatic tdc cp51m1
- siemens simatic tdc cpu555
- siemens sinumerik 840d sl
- siemens simatic s7-300 cpu 312 ifm firmware
- siemens simatic s7-300 cpu 313 firmware
- siemens simatic s7-300 cpu 314 firmware
- siemens simatic s7-300 cpu 314 ifm firmware
- siemens simatic s7-300 cpu 315-2 dp firmware
- siemens simatic s7-300 cpu 315 firmware
- siemens simatic s7-300 cpu 316-2 dp firmware
- siemens simatic s7-300 cpu 318-2 firmware
History
| Recorded | Changed | Sources |
|---|---|---|
| facts | ||
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2019-18336 is a high vulnerability (CVSS 7.5) in Siemens Simatic S7-300 Cpu Family (incl. Related Et200 Cpus And Siplus Variants), published March 10, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.72%, the 77th percentile. No source names a fixed version.