Every CVE Search/ Get API key

CVE-2019-18341

A vulnerability has been identified in SiNVR 3 Central Control Server (CCS) (all versions), SiNVR...

5.3 Medium

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability.

A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
None
Availability
None

Exploit likelihood

1.62%Up 0.8 points since Apr 14, 2021
90%50%10%1%

What each source reports

CVE List Score used 5.3

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability.

A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).

Record
CVE-2019-18341
CVSS 3.1
5.3 MediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:F/RL:U/RC:C
Weakness
CWE-287
Updated
2026-11-02
EUVDEUVD-2019-8130 5.3

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability.

A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).

Record
EUVD-2019-8130
CVSS 3.1
5.3 MediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:F/RL:U/RC:C
Updated
2026-11-03
GitHub AdvisoriesGHSA-g28c-477m-v5p9 5.3

A vulnerability has been identified in SiNVR 3 Central Control Server (CCS) (all versions), SiNVR...

A vulnerability has been identified in SiNVR 3 Central Control Server (CCS) (all versions), SiNVR 3 Video Server (all versions). The SFTP service (default port 22/tcp) of the SiNVR 3 Central Control Server (CCS) contains an authentication bypass vulnerability. A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).

Record
GHSA-g28c-477m-v5p9
CVSS 3.1
5.3 MediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Weakness
CWE-287
Updated
2026-11-02
NVD 5.3

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability.

A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).

Record
CVE-2019-18341
CVSS 3.1
5.3 MediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
CVSS 2.0
5.0 MediumAV:N/AC:L/Au:N/C:P/I:N/A:N
Weakness
CWE-287
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2019-18341 is a medium vulnerability (CVSS 5.3) in Siemens Control Center Server (ccs), published December 12, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.62%, the 76th percentile. No source names a fixed version.

References

MoveEnter Open