CVE-2019-18341
A vulnerability has been identified in SiNVR 3 Central Control Server (CCS) (all versions), SiNVR...
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability.
A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- Low
- Integrity
- None
- Availability
- None
Exploit likelihood
What each source reports
CVE List Score used
5.3
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability.
A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).
- Record
CVE-2019-18341- CVSS 3.1
- 5.3 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:F/RL:U/RC:C - Weakness
- CWE-287
- Updated
- 2026-11-02
EUVDEUVD-2019-8130
5.3
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability.
A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).
- Record
EUVD-2019-8130- CVSS 3.1
- 5.3 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:F/RL:U/RC:C - Updated
- 2026-11-03
GitHub AdvisoriesGHSA-g28c-477m-v5p9
5.3
A vulnerability has been identified in SiNVR 3 Central Control Server (CCS) (all versions), SiNVR...
A vulnerability has been identified in SiNVR 3 Central Control Server (CCS) (all versions), SiNVR 3 Video Server (all versions). The SFTP service (default port 22/tcp) of the SiNVR 3 Central Control Server (CCS) contains an authentication bypass vulnerability. A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).
- Record
GHSA-g28c-477m-v5p9- CVSS 3.1
- 5.3 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N - Weakness
- CWE-287
- Updated
- 2026-11-02
NVD
5.3
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) contains an authentication bypass vulnerability.
A remote attacker with network access to the CCS server could exploit this vulnerability to read data from the EDIR directory (for example, the list of all configured stations).
- Record
CVE-2019-18341- CVSS 3.1
- 5.3 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N - CVSS 2.0
- 5.0 Medium
AV:N/AC:L/Au:N/C:P/I:N/A:N - Weakness
- CWE-287
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2019-18341 is a medium vulnerability (CVSS 5.3) in Siemens Control Center Server (ccs), published December 12, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.62%, the 76th percentile. No source names a fixed version.