Every CVE Search/ Get API key

CVE-2019-19505

Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a stack-based buffer overflow,...

8.8 High

Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a stack-based buffer overflow, caused by improper bounds checking by the "Wireless" section in the web-UI. By sending a specially crafted hostname, a remote attacker could overflow a buffer and execute arbitrary code on the system or cause the application to crash.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

3.50%Up 2.5 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 8.8

Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a stack-based buffer overflow, caused by improper bounds checking by the "Wireless" section in the web-UI. By sending a specially crafted hostname, a remote attacker could overflow a buffer and execute arbitrary code on the system or cause the application to crash.

Record
CVE-2019-19505
CVSS 3.1
8.8 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
9.0 HighAV:N/AC:L/Au:S/C:C/I:C/A:C
Weakness
CWE-787
Updated
2026-11-02
CVE List No score

Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a stack-based buffer overflow, caused by improper bounds checking by the "Wireless" section in the web-UI. By sending a specially crafted hostname, a remote attacker could overflow a buffer and execute arbitrary code on the system or cause the application to crash.

Record
CVE-2019-19505
Updated
2026-11-02
EUVDEUVD-2019-9124 No score

Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a stack-based buffer overflow, caused by improper bounds checking by the "Wireless" section in the web-UI. By sending a specially crafted hostname, a remote attacker could overflow a buffer and execute arbitrary code on the system or cause the application to crash.

Record
EUVD-2019-9124
Updated
2026-11-03
GitHub AdvisoriesGHSA-prgr-7p65-5g7g No score

Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a stack-based buffer overflow,...

Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a stack-based buffer overflow, caused by improper bounds checking by the "Wireless" section in the web-UI. By sending a specially crafted hostname, a remote attacker could overflow a buffer and execute arbitrary code on the system or cause the application to crash.

Record
GHSA-prgr-7p65-5g7g
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2019-19505 is a high vulnerability (CVSS 8.8) in Tendacn Pa6 Firmware, published June 25, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 3.50%, the 89th percentile. No source names a fixed version.

References

MoveEnter Open