Every CVE Search/ Get API key

CVE-2019-6855

An Improper Authorization - CWE-285 vulnerability exists in EcoStruxure? Control Expert V14.0 and...

7.3 High

Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
Low
Availability
Low

Exploit likelihood

0.95%Up 0.5 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 7.3

Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.

Record
CVE-2019-6855
CVSS 3.1
7.3 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
CVSS 2.0
7.5 HighAV:N/AC:L/Au:N/C:P/I:P/A:P
Weakness
CWE-863
Updated
2026-11-02
CVE List No score

Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.

Record
CVE-2019-6855
Weakness
CWE-863
Updated
2026-11-02
EUVDEUVD-2019-16409 No score

Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the authentication process between EcoStruxure Control Expert and the M340 and M580 controllers.

Record
EUVD-2019-16409
Updated
2026-11-03
GitHub AdvisoriesGHSA-f79p-hq3g-prjw No score

An Improper Authorization - CWE-285 vulnerability exists in EcoStruxure? Control Expert V14.0 and...

An Improper Authorization - CWE-285 vulnerability exists in EcoStruxure? Control Expert V14.0 and all versions of Unity Pro (previously calledEcoStruxure? Control Expert), which could allow a bypass of the authentication process between EcoStruxure Control Expert and the controller.

Record
GHSA-f79p-hq3g-prjw
Weakness
CWE-863
Updated
2026-11-02

Affected products

Show 11 moreShow less

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2019-6855 is a high vulnerability (CVSS 7.3) in Schneider-electric Ecostruxure Control Expert, published January 6, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.95%, the 61st percentile. No source names a fixed version.

References

MoveEnter Open