Every CVE Search/ Get API key

CVE-2019-7670

Prima Systems FlexAir devices allow Authenticated Command Injection resulting in Root Remote Code...

7.2 HighPublic exploit

Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
High
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

18.0%Up 11.8 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 7.2

Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system.

Record
CVE-2019-7670
CVSS 3.1
7.2 HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
9.0 HighAV:N/AC:L/Au:S/C:C/I:C/A:C
Weakness
CWE-78
Updated
2026-11-02
CVE List No score

Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system.

Record
CVE-2019-7670
Updated
2026-11-02
EUVDEUVD-2019-17202 No score

Prima Systems FlexAir, Versions 2.3.38 and prior. The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system.

Record
EUVD-2019-17202
Updated
2026-11-03
GitHub AdvisoriesGHSA-pqmc-5wjw-632r 7.2

Prima Systems FlexAir devices allow Authenticated Command Injection resulting in Root Remote Code...

Prima Systems FlexAir devices allow Authenticated Command Injection resulting in Root Remote Code Execution.

Record
GHSA-pqmc-5wjw-632r
CVSS 3.1
7.2 HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02

Affected products

Public exploits

Links only. Every CVE stores no exploit code.

Public exploits
SourceLinkDate
Exploit-DBPrima FlexAir Access Control 2.3.38 - Remote Code Execution2019-11-12

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, Exploit-DB, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2019-7670 is a high vulnerability (CVSS 7.2) in Primasystems Flexair, published July 1, 2019. Public exploit code exists. EPSS puts the chance of exploitation in the next 30 days at 18.0%, the 97th percentile. No source names a fixed version.

References

MoveEnter Open