Every CVE Search/ Get API key

CVE-2020-10597

The affected insulin pump is designed to communicate using a wireless RF with an Insulet...

7.1 High

Delta Industrial Automation DOPSoft, Version 4.00.08.15 and prior. Multiple out-of-bounds read vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to read information and/or crash the application.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
Low
Privileges needed
None
User interaction
Required

What an attacker can affect

Confidentiality
High
Integrity
None
Availability
High

Exploit likelihood

0.80%Up 0.4 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 7.1

Delta Industrial Automation DOPSoft, Version 4.00.08.15 and prior. Multiple out-of-bounds read vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to read information and/or crash the application.

Record
CVE-2020-10597
CVSS 3.1
7.1 HighCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H
CVSS 2.0
5.8 MediumAV:N/AC:M/Au:N/C:P/I:N/A:P
Weakness
CWE-125
Updated
2026-11-02
CVE List No score

Delta Industrial Automation DOPSoft, Version 4.00.08.15 and prior. Multiple out-of-bounds read vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to read information and/or crash the application.

Record
CVE-2020-10597
Weakness
CWE-125
Updated
2026-11-02
EUVDEUVD-2020-3045 No score

Delta Industrial Automation DOPSoft, Version 4.00.08.15 and prior. Multiple out-of-bounds read vulnerabilities may be exploited by processing specially crafted project files, which may allow an attacker to read information and/or crash the application.

Record
EUVD-2020-3045
Updated
2026-11-03
GitHub AdvisoriesGHSA-xjhq-mcqp-qfx3 No score

The affected insulin pump is designed to communicate using a wireless RF with an Insulet...

The affected insulin pump is designed to communicate using a wireless RF with an Insulet manufactured Personal Diabetes Manager device. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with access to one of the affected insulin pump models may be able to modify and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.

Record
GHSA-xjhq-mcqp-qfx3
Weakness
CWE-125
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, productsEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2020-10597 is a high vulnerability (CVSS 7.1) in Delta Electronics Industrial Automation Dopsoft, published March 20, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.80%, the 57th percentile. No source names a fixed version.

References

MoveEnter Open