CVE-2020-12615
An issue was discovered in BeyondTrust Privilege Management for Windows through 5.6. When adding...
An issue was discovered in BeyondTrust Privilege Management for Windows through 5.6. When adding the Add Admin token to a process, and specifying that it runs at medium integrity with the user owning the process, this security token can be stolen and applied to arbitrary processes.
Attack profile
How easy it is to exploit
- Attack vector
- Local
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
7.8
An issue was discovered in BeyondTrust Privilege Management for Windows through 5.6. When adding the Add Admin token to a process, and specifying that it runs at medium integrity with the user owning the process, this security token can be stolen and applied to arbitrary processes.
- Record
CVE-2020-12615- CVSS 3.1
- 7.8 High
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-269
- Updated
- 2026-11-02
CVE List No score
An issue was discovered in BeyondTrust Privilege Management for Windows through 5.6. When adding the Add Admin token to a process, and specifying that it runs at medium integrity with the user owning the process, this security token can be stolen and applied to arbitrary processes.
- Record
CVE-2020-12615- Weakness
- CWE-269
- Updated
- 2026-11-02
EUVDEUVD-2020-4916 No score
An issue was discovered in BeyondTrust Privilege Management for Windows through 5.6. When adding the Add Admin token to a process, and specifying that it runs at medium integrity with the user owning the process, this security token can be stolen and applied to arbitrary processes.
- Record
EUVD-2020-4916- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-hrh7-rq69-242h
7.8
An issue was discovered in BeyondTrust Privilege Management for Windows through 5.6. When adding...
An issue was discovered in BeyondTrust Privilege Management for Windows through 5.6. When adding the Add Admin token to a process, and specifying that it runs at medium integrity with the user owning the process, this security token can be stolen and applied to arbitrary processes.
- Record
GHSA-hrh7-rq69-242h- CVSS 3.1
- 7.8 High
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-269
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2020-12615 is a high vulnerability (CVSS 7.8) in Beyondtrust Privilege Management For Windows, published December 12, 2023. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.22%, the 13th percentile. No source names a fixed version.