CVE-2020-14158
The ABUS Secvest FUMO50110 hybrid module does not have any security mechanism that ensures...
The ABUS Secvest FUMO50110 hybrid module does not have any security mechanism that ensures confidentiality or integrity of RF packets that are exchanged with an alarm panel. This makes it easier to conduct wAppLoxx authentication-bypass attacks.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- None
Exploit likelihood
What each source reports
NVD Score used
9.1
The ABUS Secvest FUMO50110 hybrid module does not have any security mechanism that ensures confidentiality or integrity of RF packets that are exchanged with an alarm panel. This makes it easier to conduct wAppLoxx authentication-bypass attacks.
- Record
CVE-2020-14158- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N - CVSS 2.0
- 6.4 Medium
AV:N/AC:L/Au:N/C:P/I:P/A:N - Weakness
- CWE-287
- Updated
- 2026-11-02
CVE List No score
The ABUS Secvest FUMO50110 hybrid module does not have any security mechanism that ensures confidentiality or integrity of RF packets that are exchanged with an alarm panel. This makes it easier to conduct wAppLoxx authentication-bypass attacks.
- Record
CVE-2020-14158- Updated
- 2026-11-02
EUVDEUVD-2020-6315 No score
The ABUS Secvest FUMO50110 hybrid module does not have any security mechanism that ensures confidentiality or integrity of RF packets that are exchanged with an alarm panel. This makes it easier to conduct wAppLoxx authentication-bypass attacks.
- Record
EUVD-2020-6315- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-4vh5-9j7r-fhh8 No score
The ABUS Secvest FUMO50110 hybrid module does not have any security mechanism that ensures...
The ABUS Secvest FUMO50110 hybrid module does not have any security mechanism that ensures confidentiality or integrity of RF packets that are exchanged with an alarm panel. This makes it easier to conduct wAppLoxx authentication-bypass attacks.
- Record
GHSA-4vh5-9j7r-fhh8- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2020-14158 is a critical vulnerability (CVSS 9.1) in Abus Secvest Hybrid Fumo50110 Firmware, published July 30, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.84%, the 79th percentile. No source names a fixed version.