CVE-2020-14525
Philips Clinical Collaboration Platform Improper Neutralization of Script in Attributes in a Web Page
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users.
Attack profile
How easy it is to exploit
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- Low
- Integrity
- None
- Availability
- None
Exploit likelihood
What each source reports
CVE List Score used
3.5
Philips Clinical Collaboration Platform Improper Neutralization of Script in Attributes in a Web Page
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users.
- Record
CVE-2020-14525- CVSS 3.1
- 3.5 Low
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N - Weakness
- CWE-83
- Updated
- 2026-11-02
EUVDEUVD-2020-6661
3.5
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users.
- Record
EUVD-2020-6661- CVSS 3.1
- 3.5 Low
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-779w-7mcf-pvxf
3.5
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The software does not...
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users.
- Record
GHSA-779w-7mcf-pvxf- CVSS 3.1
- 3.5 Low
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N - Weakness
- CWE-83
- Updated
- 2026-11-02
NVD
3.5
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users.
- Record
CVE-2020-14525- CVSS 3.1
- 3.5 Low
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N - CVSS 2.0
- 2.7 Low
AV:A/AC:L/Au:S/C:P/I:N/A:N - Weakness
- CWE-83
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short