CVE-2020-16212
Philips Patient Monitoring Devices Exposure of Resource to Wrong Sphere
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges.
Attack profile
How easy it is to exploit
- Attack vector
- Physical
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
6.8
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges.
- Record
CVE-2020-16212- CVSS 3.1
- 6.8 Medium
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 4.6 Medium
AV:L/AC:L/Au:N/C:P/I:P/A:P - Weakness
- CWE-668
- Updated
- 2026-11-02
CVE List No score
Philips Patient Monitoring Devices Exposure of Resource to Wrong Sphere
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges.
- Record
CVE-2020-16212- Weakness
- CWE-668
- Updated
- 2026-11-02
EUVDEUVD-2020-8178 No score
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges.
- Record
EUVD-2020-8178- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-33r4-hmp8-j73x
6.8
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point...
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges.
- Record
GHSA-33r4-hmp8-j73x- CVSS 3.1
- 6.8 Medium
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-668
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2020-16212 is a medium vulnerability (CVSS 6.8) in Philips Patient Information Center Ix (picix), published September 11, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.37%, the 31st percentile. No source names a fixed version.