Philips Patient Monitoring Devices Improper Input Validation

6.5 Medium

In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.

Attack profile

How easy it is to exploit

Attack vector
Adjacent network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
None
Integrity
None
Availability
High

Exploit likelihood

0.70%Up 0.3 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 6.5

In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.

Record
CVE-2020-16216
CVSS 3.1
6.5 MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS 2.0
6.1 MediumAV:A/AC:L/Au:N/C:N/I:N/A:C
Weakness
CWE-20
Updated
2026-11-02
CVE List No score

Philips Patient Monitoring Devices Improper Input Validation

In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.

Record
CVE-2020-16216
Weakness
CWE-20
Updated
2026-11-02
EUVDEUVD-2020-8182 No score

In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.

Record
EUVD-2020-8182
Updated
2026-11-03
GitHub AdvisoriesGHSA-r3cv-8v59-5mh6 6.5

Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point...

Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.

Record
GHSA-r3cv-8v59-5mh6
CVSS 3.1
6.5 MediumCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness
CWE-20
Updated
2026-11-02

Affected products

Show 3 moreShow less

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2020-16216 is a medium vulnerability (CVSS 6.5) in Philips Intellivue, published September 11, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.70%, the 53rd percentile. No source names a fixed version.

References

MoveEnter Open