CVE-2020-16218
Philips Patient Monitoring Devices Cross-site Scripting
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application.
Attack profile
How easy it is to exploit
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- Low
- Integrity
- None
- Availability
- None
Exploit likelihood
What each source reports
NVD Score used
3.5
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application.
- Record
CVE-2020-16218- CVSS 3.1
- 3.5 Low
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N - CVSS 2.0
- 2.7 Low
AV:A/AC:L/Au:S/C:P/I:N/A:N - Weakness
- CWE-79
- Updated
- 2026-11-02
CVE List No score
Philips Patient Monitoring Devices Cross-site Scripting
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application.
- Record
CVE-2020-16218- Weakness
- CWE-79
- Updated
- 2026-11-02
EUVDEUVD-2020-8184 No score
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application.
- Record
EUVD-2020-8184- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-9p4m-gvr2-2mpp
3.5
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point...
Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application.
- Record
GHSA-9p4m-gvr2-2mpp- CVSS 3.1
- 3.5 Low
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N - Weakness
- CWE-79
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2020-16218 is a low vulnerability (CVSS 3.5) in Philips Patient Information Center Ix (picix), published September 11, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.65%, the 51st percentile. No source names a fixed version.