CVE-2020-20741
Incorrect Access Control in Beckhoff Automation GmbH & Co. KG CX9020 with firmware version...
Incorrect Access Control in Beckhoff Automation GmbH & Co. KG CX9020 with firmware version CX9020_CB3011_WEC7_HPS_v602_TC31_B4016.6 allows remote attackers to bypass authentication via the "CE Remote Display Tool" as it does not close the incoming connection on the Windows CE side if the credentials are incorrect.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
NVD Score used
9.8
Incorrect Access Control in Beckhoff Automation GmbH & Co. KG CX9020 with firmware version CX9020_CB3011_WEC7_HPS_v602_TC31_B4016.6 allows remote attackers to bypass authentication via the "CE Remote Display Tool" as it does not close the incoming connection on the Windows CE side if the credentials are incorrect.
- Record
CVE-2020-20741- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 7.5 High
AV:N/AC:L/Au:N/C:P/I:P/A:P - Updated
- 2026-11-02
CVE List No score
Incorrect Access Control in Beckhoff Automation GmbH & Co. KG CX9020 with firmware version CX9020_CB3011_WEC7_HPS_v602_TC31_B4016.6 allows remote attackers to bypass authentication via the "CE Remote Display Tool" as it does not close the incoming connection on the Windows CE side if the credentials are incorrect.
- Record
CVE-2020-20741- Updated
- 2026-11-02
EUVDEUVD-2020-13521 No score
Incorrect Access Control in Beckhoff Automation GmbH & Co. KG CX9020 with firmware version CX9020_CB3011_WEC7_HPS_v602_TC31_B4016.6 allows remote attackers to bypass authentication via the "CE Remote Display Tool" as it does not close the incoming connection on the Windows CE side if the credentials are incorrect.
- Record
EUVD-2020-13521- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-rprh-9x53-mwjp No score
Incorrect Access Control in Beckhoff Automation GmbH & Co. KG CX9020 with firmware version...
Incorrect Access Control in Beckhoff Automation GmbH & Co. KG CX9020 with firmware version CX9020_CB3011_WEC7_HPS_v602_TC31_B4016.6 allows remote attackers to bypass authentication via the "CE Remote Display Tool" as it does not close the incoming connection on the Windows CE side if the credentials are incorrect.
- Record
GHSA-rprh-9x53-mwjp- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2020-20741 is a critical vulnerability (CVSS 9.8) in Beckhoff Cx9020, published July 23, 2021. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.56%, the 75th percentile. No source names a fixed version.