Every CVE Search/ Get API key

CVE-2020-27251

A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This...

9.8 Critical

A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious port ranges, which could result in remote code execution.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

6.82%Up 5.9 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 9.8

A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious port ranges, which could result in remote code execution.

Record
CVE-2020-27251
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
7.5 HighAV:N/AC:L/Au:N/C:P/I:P/A:P
Weakness
CWE-122
Updated
2026-11-02
CVE List No score

A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious port ranges, which could result in remote code execution.

Record
CVE-2020-27251
Weakness
CWE-122
Updated
2026-11-02
EUVDEUVD-2020-19764 No score

A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious port ranges, which could result in remote code execution.

Record
EUVD-2020-19764
Updated
2026-11-03
GitHub AdvisoriesGHSA-7hx6-pmgh-3p98 No score

A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This...

A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious port ranges, which could result in remote code execution.

Record
GHSA-7hx6-pmgh-3p98
Weakness
CWE-122
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
facts
aliases, productsEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2020-27251 is a critical vulnerability (CVSS 9.8) in Rockwell Automation Factorytalk Linx, published November 26, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 6.82%, the 94th percentile. No source names a fixed version.

References

MoveEnter Open