Every CVE Search/ Get API key

CVE-2020-6967

In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the...

9.8 Critical

In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

5.50%Up 5.1 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 9.8

In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.

Record
CVE-2020-6967
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
10.0 HighAV:N/AC:L/Au:N/C:C/I:C/A:C
Weakness
CWE-502
Updated
2026-11-02
CVE List No score

In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.

Record
CVE-2020-6967
Weakness
CWE-502
Updated
2026-11-02
EUVDEUVD-2020-28107 No score

In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.

Record
EUVD-2020-28107
Updated
2026-11-03
GitHub AdvisoriesGHSA-fmpr-x9v2-r3jj 9.8

In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the...

In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.

Record
GHSA-fmpr-x9v2-r3jj
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-502
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
facts
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2020-6967 is a critical vulnerability (CVSS 9.8) in Rockwellautomation Factorytalk Services Platform, published March 23, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 5.50%, the 92nd percentile. No source names a fixed version.

References

MoveEnter Open