CVE-2020-6998
Rockwell Automation CompactLogix 5370 and ControlLogix 5570 Controllers Improper Input Validation
The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which may cause denial-of-service conditions in communications with other products.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- None
- Integrity
- None
- Availability
- Low
Exploit likelihood
What each source reports
CVE List Score used
5.8
Rockwell Automation CompactLogix 5370 and ControlLogix 5570 Controllers Improper Input Validation
The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which may cause denial-of-service conditions in communications with other products.
- Record
CVE-2020-6998- CVSS 3.1
- 5.8 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:L - Weakness
- CWE-20
- Updated
- 2026-11-02
EUVDEUVD-2020-28138
5.8
The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which may cause denial-of-service conditions in communications with other products.
- Record
EUVD-2020-28138- CVSS 3.1
- 5.8 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:L - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-9r87-pc5m-9w97
8.6
The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and...
The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which may cause denial-of-service conditions in communications with other products.
- Record
GHSA-9r87-pc5m-9w97- CVSS 3.1
- 8.6 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H - Weakness
- CWE-20
- Updated
- 2026-11-02
NVD
5.8
The connection establishment algorithm found in Rockwell Automation CompactLogix 5370 and ControlLogix 5570 versions 33 and prior does not sufficiently manage its control flow during execution, creating an infinite loop. This may allow an attacker to send specially crafted CIP packet requests to a controller, which may cause denial-of-service conditions in communications with other products.
- Record
CVE-2020-6998- CVSS 3.1
- 5.8 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:L - CVSS 3.1
- 8.6 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H - Weakness
- CWE-20
- Updated
- 2026-11-02
Affected products
- rockwell automation controllogix 5570 controllers
- rockwell automation armor compact guardlogix 5370 controllers
- rockwell automation armor guardlogix safety controllers
- rockwell automation compact guardlogix 5370 controllers
- rockwell automation compactlogix 5370 l1 controllers
- rockwell automation compactlogix 5370 l2 controllers
- rockwell automation compactlogix 5370 l3 controllers
- rockwellautomation armor compact guardlogix 5370 firmware
- rockwellautomation compact guardlogix 5370 firmware
- rockwellautomation compactlogix 5370 l1 firmware
- rockwellautomation compactlogix 5370 l2 firmware
- rockwellautomation compactlogix 5370 l3 firmware
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2020-6998 is a medium vulnerability (CVSS 5.8) in Rockwell Automation Controllogix 5570 Controllers, published July 27, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 3.16%, the 88th percentile. No source names a fixed version.