Every CVE Search/ Get API key

CVE-2020-7486

**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability could cause TCM modules to reset when...

7.5 High

VERSION NOT SUPPORTED WHEN ASSIGNED A vulnerability could cause TCM modules to reset when under high network load in TCM v10.4.x and in system v10.3.x. This vulnerability was discovered and remediated in version v10.5.x on August 13, 2009. TCMs from v10.5.x and on will no longer exhibit this behavior.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
None
Integrity
None
Availability
High

Exploit likelihood

1.64%Up 1.0 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 7.5

VERSION NOT SUPPORTED WHEN ASSIGNED A vulnerability could cause TCM modules to reset when under high network load in TCM v10.4.x and in system v10.3.x. This vulnerability was discovered and remediated in version v10.5.x on August 13, 2009. TCMs from v10.5.x and on will no longer exhibit this behavior.

Record
CVE-2020-7486
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS 2.0
5.0 MediumAV:N/AC:L/Au:N/C:N/I:N/A:P
Weakness
CWE-400
Updated
2026-11-02
CVE List No score

VERSION NOT SUPPORTED WHEN ASSIGNED A vulnerability could cause TCM modules to reset when under high network load in TCM v10.4.x and in system v10.3.x. This vulnerability was discovered and remediated in version v10.5.x on August 13, 2009. TCMs from v10.5.x and on will no longer exhibit this behavior.

Record
CVE-2020-7486
Updated
2026-11-02
EUVDEUVD-2020-28611 No score

VERSION NOT SUPPORTED WHEN ASSIGNED A vulnerability could cause TCM modules to reset when under high network load in TCM v10.4.x and in system v10.3.x. This vulnerability was discovered and remediated in version v10.5.x on August 13, 2009. TCMs from v10.5.x and on will no longer exhibit this behavior.

Record
EUVD-2020-28611
Updated
2026-11-03
GitHub AdvisoriesGHSA-vxcj-679q-r6q8 No score

**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability could cause TCM modules to reset when...

VERSION NOT SUPPORTED WHEN ASSIGNED A vulnerability could cause TCM modules to reset when under high network load in TCM v10.4.x and in system v10.3.x. This vulnerability was discovered and remediated in version v10.5.x on August 13, 2009. TCMs from v10.5.x and on will no longer exhibit this behavior.

Record
GHSA-vxcj-679q-r6q8
Weakness
CWE-400
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
facts
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2020-7486 is a high vulnerability (CVSS 7.5) in Schneider-electric Tricon Tcm 4351 Firmware, published April 15, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.64%, the 76th percentile. No source names a fixed version.