CVE-2020-7592
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS...
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.
Attack profile
How easy it is to exploit
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- None
- Availability
- None
Exploit likelihood
What each source reports
NVD Score used
6.5
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.
- Record
CVE-2020-7592- CVSS 3.1
- 6.5 Medium
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - CVSS 2.0
- 3.3 Low
AV:A/AC:L/Au:N/C:P/I:N/A:N - Weakness
- CWE-319
- Updated
- 2026-11-02
CVE List No score
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.
- Record
CVE-2020-7592- Weakness
- CWE-319
- Updated
- 2026-11-02
EUVDEUVD-2020-28717 No score
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.
- Record
EUVD-2020-28717- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-mhgv-m547-f82g No score
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS...
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.
- Record
GHSA-mhgv-m547-f82g- Updated
- 2026-11-02
Affected products
- siemens simatic hmi basic panels 2nd generation (incl. siplus variants)
- siemens simatic hmi comfort panels (incl. siplus variants)
- siemens simatic wincc runtime advanced
- siemens simatic hmi basic panels 1st generation
- siemens simatic hmi basic panels 2nd generation
- siemens simatic hmi comfort panels firmware
- siemens simatic hmi ktp700f mobile arctic firmware
- siemens simatic hmi mobile panels 2nd generation firmware
- siemens ag simatic hmi basic panels 1st generation (incl. siplus variants)
- siemens ag simatic hmi basic panels 2nd generation (incl. siplus variants)
- siemens ag simatic hmi comfort panels (incl. siplus variants)
- siemens ag simatic hmi ktp700f mobile arctic
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases, products | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2020-7592 is a medium vulnerability (CVSS 6.5) in Siemens Simatic Hmi Basic Panels 2nd Generation (incl. Siplus Variants), published July 14, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.33%, the 26th percentile. No source names a fixed version.