Every CVE Search/ Get API key

CVE-2020-7594

MultiTech Conduit MTCDT-LVW2-24XX 1.4.17-ocea-13592 devices allow remote authenticated...

7.2 High

MultiTech Conduit MTCDT-LVW2-24XX 1.4.17-ocea-13592 devices allow remote authenticated administrators to execute arbitrary OS commands by navigating to the Debug Options page and entering shell metacharacters in the interface JSON field of the ping function.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
High
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

2.49%Up 2.0 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 7.2

MultiTech Conduit MTCDT-LVW2-24XX 1.4.17-ocea-13592 devices allow remote authenticated administrators to execute arbitrary OS commands by navigating to the Debug Options page and entering shell metacharacters in the interface JSON field of the ping function.

Record
CVE-2020-7594
CVSS 3.1
7.2 HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
9.0 HighAV:N/AC:L/Au:S/C:C/I:C/A:C
Weakness
CWE-78
Updated
2026-11-02
CVE List No score

MultiTech Conduit MTCDT-LVW2-24XX 1.4.17-ocea-13592 devices allow remote authenticated administrators to execute arbitrary OS commands by navigating to the Debug Options page and entering shell metacharacters in the interface JSON field of the ping function.

Record
CVE-2020-7594
Updated
2026-11-02
EUVDEUVD-2020-28719 No score

MultiTech Conduit MTCDT-LVW2-24XX 1.4.17-ocea-13592 devices allow remote authenticated administrators to execute arbitrary OS commands by navigating to the Debug Options page and entering shell metacharacters in the interface JSON field of the ping function.

Record
EUVD-2020-28719
Updated
2026-11-03
GitHub AdvisoriesGHSA-prjf-h86p-335v No score

MultiTech Conduit MTCDT-LVW2-24XX 1.4.17-ocea-13592 devices allow remote authenticated...

MultiTech Conduit MTCDT-LVW2-24XX 1.4.17-ocea-13592 devices allow remote authenticated administrators to execute arbitrary OS commands by navigating to the Debug Options page and entering shell metacharacters in the interface JSON field of the ping function.

Record
GHSA-prjf-h86p-335v
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2020-7594 is a high vulnerability (CVSS 7.2) in Multitech Conduit Mtcdt-lvw2-246a Firmware, published January 21, 2020. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 2.49%, the 84th percentile. No source names a fixed version.

References

MoveEnter Open