Every CVE Search/ Get API key

CVE-2021-20141

An unauthenticated command injection vulnerability exists in the parameters of operation 32 in...

8.8 High

An unauthenticated command injection vulnerability exists in the parameters of operation 32 in the controller_server service on Gryphon Tower routers. An unauthenticated remote attacker on the same network can execute commands as root on the device by sending a specially crafted malicious packet to the controller_server service on port 9999.

Attack profile

How easy it is to exploit

Attack vector
Adjacent network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

3.71%Up 2.8 points since Dec 10, 2021
90%50%10%1%

What each source reports

NVD Score used 8.8

An unauthenticated command injection vulnerability exists in the parameters of operation 32 in the controller_server service on Gryphon Tower routers. An unauthenticated remote attacker on the same network can execute commands as root on the device by sending a specially crafted malicious packet to the controller_server service on port 9999.

Record
CVE-2021-20141
CVSS 3.1
8.8 HighCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
8.3 HighAV:A/AC:L/Au:N/C:C/I:C/A:C
Weakness
CWE-78
Updated
2026-11-02
CVE List No score

An unauthenticated command injection vulnerability exists in the parameters of operation 32 in the controller_server service on Gryphon Tower routers. An unauthenticated remote attacker on the same network can execute commands as root on the device by sending a specially crafted malicious packet to the controller_server service on port 9999.

Record
CVE-2021-20141
Updated
2026-11-02
EUVDEUVD-2021-7598 No score

An unauthenticated command injection vulnerability exists in the parameters of operation 32 in the controller_server service on Gryphon Tower routers. An unauthenticated remote attacker on the same network can execute commands as root on the device by sending a specially crafted malicious packet to the controller_server service on port 9999.

Record
EUVD-2021-7598
Updated
2026-11-03
GitHub AdvisoriesGHSA-xhx3-2rfr-6x58 No score

An unauthenticated command injection vulnerability exists in the parameters of operation 32 in...

An unauthenticated command injection vulnerability exists in the parameters of operation 32 in the controller_server service on Gryphon Tower routers. An unauthenticated remote attacker on the same network can execute commands as root on the device by sending a specially crafted malicious packet to the controller_server service on port 9999.

Record
GHSA-xhx3-2rfr-6x58
Weakness
CWE-78
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2021-20141 is a high vulnerability (CVSS 8.8) in Gryphonconnect Gryphon Tower Firmware, published December 9, 2021. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 3.71%, the 89th percentile. No source names a fixed version.