Every CVE Search/ Get API key

CVE-2021-22713

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability...

7.5 High

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
None
Integrity
None
Availability
High

Exploit likelihood

1.21%Up 0.8 points since Apr 14, 2021
90%50%10%1%

What each source reports

NVD Score used 7.5

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot.

Record
CVE-2021-22713
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS 2.0
7.8 HighAV:N/AC:L/Au:N/C:N/I:N/A:C
Weakness
CWE-119
Updated
2026-11-02
CVE List 7.5

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot.

Record
CVE-2021-22713
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness
CWE-119
Updated
2026-11-02
EUVDEUVD-2021-9848 7.5

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot.

Record
EUVD-2021-9848
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Updated
2026-11-02
GitHub AdvisoriesGHSA-fp3q-76ww-6mv4 7.5

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability...

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot.

Record
GHSA-fp3q-76ww-6mv4
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness
CWE-119
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2021-22713 is a high vulnerability (CVSS 7.5) in Schneider-electric Ion7650 Firmware, published March 11, 2021. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.21%, the 68th percentile. No source names a fixed version.

References

MoveEnter Open