Every CVE Search/ Get API key

CVE-2021-22795

A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection...

9.1 Critical

A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
High
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

3.12%Up 0.4 points since Mar 29, 2022
90%50%10%1%

What each source reports

CVE List Score used 9.1

A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)

Record
CVE-2021-22795
CVSS 3.1
9.1 CriticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02
EUVDEUVD-2021-9930 9.1

A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)

Record
EUVD-2021-9930
CVSS 3.1
9.1 CriticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Updated
2026-11-03
GitHub AdvisoriesGHSA-9pc8-6crf-r3rv 9.8

A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection...

A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)

Record
GHSA-9pc8-6crf-r3rv
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02
NVD 9.1

A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)

Record
CVE-2021-22795
CVSS 3.1
9.1 CriticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
7.5 HighAV:N/AC:L/Au:N/C:P/I:P/A:P
Weakness
CWE-78
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
facts
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2021-22795 is a critical vulnerability (CVSS 9.1) in Schneider Electric Struxureware Data Center Expert, published March 28, 2022. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 3.12%, the 87th percentile. No source names a fixed version.

References

MoveEnter Open